Mathematical model of thrombin generation and bleeding phenotype in Amish carriers of Factor IX:C deficiency vs. controls
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Mathematical model of thrombin generation and bleeding phenotype in Amish carriers of Factor IX:C deficiency vs. controls

Filetype[PDF-897.82 KB]


English

Details:

  • Alternative Title:
    Thromb Res
  • Personal Author:
  • Description:
    Introduction

    Factor IX:C (FIX:C) levels vary in hemophilia B carriers even in pedigrees with a unifying genetic defect. Analyzing the balance between pro-and anticoagulants might increase our understanding of carriers’ bleeding potential.

    Aim

    In this research study, we evaluated bleeding scores (BS) and a novel mathematical model of thrombin generation (TG) in Amish FIX:C deficient carriers and controls.

    Methods

    Blood samples and BS were obtained from post-menarchal females, including 59 carriers and 57 controls from the same extended pedigree. Factors II, V, VII, VIII, IX, X, antithrombin, tissue factor pathway inhibitor and protein C were assayed to generate mathematical models of TG in response to 5pM tissue factor (TF) and for TF + thrombomodulin. BS was based on a modification of the MCMDM-1VWD scoring system.

    Results

    Carriers had a lower mean FIX:C (68% vs. 119%), von Willebrand factor antigen (108 vs.133) and Tissue activatable fibrinolysis inhibitor (103 vs. 111) compared to controls; both groups had a similar mean BS. Carriers demonstrated significantly lower TG parameters on both mathematical models compared to controls. Carriers with FIX:C ≤ 50% had lower TG curves than those > 50% but similar BS.

    Conclusion

    Thrombin generation showed significant differences between carriers and controls, between low (≤50%) and high (> 50%) FIX:C carriers, and specifically in the TF + thrombomodulin model, between high FIX:C carriers and controls, although the BS were not different.

  • Subjects:
  • Source:
  • Pubmed ID:
    31446339
  • Pubmed Central ID:
    PMC7071813
  • Document Type:
  • Funding:
  • Volume:
    182
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

You May Also Like

Checkout today's featured content at stacks.cdc.gov