The Study of In Vivo X-Ray Fluorescence (XRF) Technique for Gadolinium (Gd) Measurements in Human Bone
-
2016/08/01
-
Details
-
Personal Author:
-
Description:An in vivo K x-ray fluorescence system, based on 109Cd source, for the detection of gadolinium has been investigated. Gd is of interest because of the extensive use of Gd-based contrast agents in MR imaging. A human simulating bone phantom set has been developed. The phantoms were doped with seven concentrations of Gd. Additional elements important for in vivo x-ray fluorescence, Na, Cl and Ca, were also included to create an overall elemental composition consistent with the Reference Man. A new 5 GBq 109Cd source was purchased to improve the source activity in comparison to the previous study (0.17 GBq). The previously published minimum detection limit (MDL) for Gd phantom measurements using KXRF system was 3.3 ppm. In this study the minimum detection limit for bare bone phantoms was found to reduce the MDL to 0.8, a factor of 4.1. The previous published data used only three layers of plastic as soft tissue equivalent materials and found the MDL of 4-4.8 ppm. In this study we have used the plastic with more realistic thicknesses to simulate a soft tissue at tibia. The detection limits for phantoms with Lucite as a tissue equivalent, using a new source, was determined to be 1.81 to 3.47 ppm (µg Gd per gram phantom). Our next study would be testing an in vivo K x-ray fluorescence system, based on 109Cd source on human volunteers who went through MR imaging and were injected by Gd. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1748-0221
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:11
-
Issue:8
-
NIOSHTIC Number:nn:20069156
-
Citation:J Instrum 2016 Aug; 11(8):T08001
-
Contact Point Address:F. Mostafaei, School of Health Sciences, Purdue University, West Lafayette, IN 47907, U.S.A.
-
Email:fmostafa@purdue.edu
-
CAS Registry Number:
-
Federal Fiscal Year:2016
-
Performing Organization:Purdue University, West Lafayette, Indiana
-
Peer Reviewed:True
-
Start Date:20120701
-
Source Full Name:Journal of Instrumentation
-
End Date:20150630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d4077c0b9861a3249eee94404b52177cb215efd6d685dd7183ea35e435ee33589d6c492ad38da5b602774b0073cd3011046087cb4f01fbfaba29f373f3b873a7
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like