U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Field-based performance of three pre-market rapid hepatitis C virus antibody assays in STAHR (Study to Assess Hepatitis C Risk) among young adults who inject drugs in San Diego, CA☆

Supporting Files
File Language:
English


Details

  • Alternative Title:
    J Clin Virol
  • Personal Author:
  • Description:
    Background ; Approximately 4.1 million Americans are estimated to have been infected with hepatitis C virus (HCV), 45–85% of whom are unaware of their infection. Persons who inject drugs (PWID) account for 55.8% of all persons with HCV antibody (anti-HCV) in the U.S. PWID have limited access to healthcare and are infrequently tested for anti-HCV using conventional laboratory assays. ; Objective ; To evaluate performance characteristics (sensitivity and specificity) of three, pre-market rapid point-of-care tests (one oral fluid and two finger-stick assays) from two manufacturers (Chembio and MedMira) in settings providing services to young adult PWID in San Diego, CA. ; Study design ; Behavioral risk assessment surveys and testing for HCV were conducted among persons who reported injection drug use (IDU) within the past 6 months as part of the Study to Assess Hepatitis C Risk (STAHR) among PWID aged 18–40 years in 2009–2010. Sensitivity and specificity of the rapid anti-HCV assays were evaluated among STAHR participants, using two commonly used testing algorithms. ; Results ; Variability in sensitivity (76.6–97.1%) and specificity (99.0–100.0%) was found across assays. The highest sensitivity achieved for the Chembio finger-stick blood, Chembio oral fluid and MedMira finger-stick blood tests was 97.1%, 85.4% and 80.0% respectively; the highest specificity was 99.0%, 100.0% and 100.0%, respectively. In multivariate analysis false negative anti-HCV results were associated with female sex for the MedMira blood assay. ; Conclusions ; Sensitive anti-HCV rapid assays are appropriate and feasible for high-prevalence, high-risk populations such as young PWID.
  • Subjects:
  • Source:
    J Clin Virol. 54(3):213-217.
  • Pubmed ID:
    22560051
  • Pubmed Central ID:
    PMC5484575
  • Document Type:
  • Funding:
  • Place as Subject:
  • Volume:
    54
  • Issue:
    3
  • Download URL:
  • File Type:
    Filetype[PDF - 321.94 KB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:216bcf9d0552539c72544d69d261fadb57a4d5fee22c28daa787011076fd2455
File Language:
English
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.