Comparison of Two Automated Solid Phase Extractions for the Detection of Ten Fentanyl Analogs and Metabolites in Human Urine Using Liquid Chromatography Tandem Mass Spectrometry

Supporting Files
File Language:
English


Details

  • Alternative Title:
    J Chromatogr B Analyt Technol Biomed Life Sci
  • Personal Author:
  • Description:
    Two types of automated solid phase extraction (SPE) were assessed for the determination of human exposure to fentanyls in urine. High sensitivity is required to detect these compounds following exposure because of the low dose required for therapeutic effect and the rapid clearance from the body for these compounds. To achieve this sensitivity, two acceptable methods for the detection of human exposure to seven fentanyl analogs and three metabolites were developed using either off-line 96-well plate SPE or on-line SPE. Each system offers different advantages: off-line 96-well plate SPE allows for high throughput analysis of many samples, which is needed for large sample numbers, while on-line SPE removes almost all analyst manipulation of the samples, minimizing the analyst time needed for sample preparation. Both sample preparations were coupled with reversed phase liquid chromatography and isotope dilution tandem mass spectrometry (LC-MS/MS) for analyte detection. For both methods, the resulting precision was within 15%, the accuracy within 25%, and the sensitivity was comparable with the limits of detection ranging from 0.002ng/mL to 0.041ng/mL. Additionally, matrix effects were substantially decreased from previous reports for both extraction protocols. The results of this comparison showed that both methods were acceptable for the detection of exposures to fentanyl analogs and metabolites in urine.
  • Keywords:
  • Source:
    J Chromatogr B Analyt Technol Biomed Life Sci. 962:52-58
  • Pubmed ID:
    24893271
  • Pubmed Central ID:
    PMC4812561
  • Document Type:
  • Funding:
  • Volume:
    962
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:07ba8ee748aebbb653b0e9bbb0b3422a923fed6c3bc6a521a8c5ffcac34becd4
  • Download URL:
  • File Type:
    Filetype[PDF - 652.12 KB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.