U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

A high-throughput LC-MS/MS method suitable for population biomonitoring measures five serum folate vitamers and one oxidation product1

Supporting Files
File Language:
English


Details

  • Alternative Title:
    Anal Bioanal Chem
  • Personal Author:
  • Description:
    Small specimen volume and high sample throughput are key features needed for routine methods used for population biomonitoring. We modified our routine eight-probe solid phase extraction (SPE) LC-MS/MS method for the measurement of five folate vitamers [5-methyltetrahydrofolate (5-methylTHF), folic acid (FA), plus three minor forms: THF, 5-formylTHF, 5,10-methenylTHF] and one oxidation product of 5-methylTHF (MeFox) to require less serum volume (150 μL instead of 275 μL) by using 96-well SPE plates with 50 mg instead of 100 mg phenyl sorbent and to provide faster throughput by using a 96-probe SPE system. Total imprecision (10 days, two replicates/day) for three serum quality control pools was 2.8-3.6% for 5-methylTHF (19.5-51.1 nmol/L), 6.6-8.7% for FA (0.72-11.4 nmol/L), and ≤11.4% for the minor folate forms (<1-5 nmol/L). The mean (±SE) recoveries of folates spiked into serum (3 days, four levels, two replicates/level) were: 5-methylTHF, 99.4 ± 3.6%; FA, 100 ± 1.8%; minor folates, 91.7-108%. SPE extraction efficiencies were ≥85%, except for THF (78%). Limits of detection were ≤0.3 nmol/L. The new method correlated well with our routine method [n = 150, r = 0.99 for 5-methylTHF, FA, and total folate (tFOL, sum of folate forms)] and produced slightly higher tFOL (5.6%) and 5-methylTHF (7.3%) concentrations, likely due to the faster 96-probe SPE process (1 vs. 5 h), resulting in improved SPE efficiency and recovery compared to the eight-probe SPE method. With this improved LC-MS/MS method, 96 samples can be processed in ~2 h, and all relevant folate forms can be accurately measured using a small serum volume.
  • Subjects:
  • Keywords:
  • Source:
    Anal Bioanal Chem. 405(13):4549-4560
  • Pubmed ID:
    23462981
  • Pubmed Central ID:
    PMC5326548
  • Document Type:
  • Funding:
  • Volume:
    405
  • Issue:
    13
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:942b2ecd9fcaa1e17c3563f8fd01d41628cd37032e12efaa5fb87a05a4906b5c
  • Download URL:
  • File Type:
    Filetype[PDF - 692.85 KB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.