Methods for the measurement of insertion loss of hearing protection devices in continuous or impulsive noise using microphone-in-real-ear or acoustic test fixture procedures.
Public Domain
-
2010/01/01
-
Details
-
Personal Author:Baade PK ; Beranek LL ; Berger EH ; Brooks BM ; Campanella AJ ; Eldred KM ; Finegold LS ; Godfrey RD ; Hellweg RD ; Lang WW ; Lubman D ; Michaud D ; Miller NP ; Murphy, William J. ; Nobile MA ; Peppin RJ ; Schmitt J ; Schomer PD ; Sutherland LC ; Thornton WR ; Wilber LA ; Winzer GE ; Wong GSK ; Baade PK ; Beranek LL ; Berger EH ; Brooks BM ; Campanella AJ ; Eldred KM ; Finegold LS ; Godfrey RD ; Hellweg RD ; Lang WW ; Lubman D ; Michaud D ; Miller NP ; Murphy, William J. ; Nobile MA ; Peppin RJ ; Schmitt J ; Schomer PD ; Sutherland LC ; Thornton WR ; Wilber LA ; Winzer GE ; Wong GSK
-
Corporate Authors:
-
Description:This standard specifies microphone-in-real-ear (MIRE) methods for the measurement of the insertion loss of active and passive circumaural earmuffs, helmets, and communications headsets, and specifies acoustic test fixture (ATF) methods for the measurement of the insertion loss of active and passive earplugs, earmuffs, helmets, and communications headsets. The MIRE methods are appropriate for use with continuous noise whereas the ATF methods may be used with both continuous noise and high-level impulsive noise test signals. The standard contains information on instrumentation, calibration, and electroacoustic requirements, procedures for determining sound pressure levels in the ear with and without the hearing protection devices in place, and procedures for calculating the corresponding insertion loss values. The standard also describes how to combine the active contribution of insertion loss for active devices measured using the MIRE method with the passive real-ear attenuation measured in accordance with ANSI/ASA S12.6 to obtain an attenuation value for use in estimating sound pressure levels for active protectors in accordance with ANSI/ASA S12.68. Requirements for reporting of the data are also described. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-53
-
NIOSHTIC Number:nn:20036585
-
Citation:Melville: NY: Acoustical Society of America, ANSI/ASA S12.42-2010, 2010 Jan; :1-53
-
Federal Fiscal Year:2010
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:Methods for the measurement of insertion loss of hearing protection devices in continuous or impulsive noise using microphone-in-real-ear or acoustic test fixture procedures
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like