Characterization of Hazardous-Gas Releases by Tracer-Gas Simulation.
Public Domain
-
1989/01/01
-
By Orcutt JJ
Details
-
Personal Author:
-
Description:One of the major hazards in the semiconductor industry involved the possible exposure to hazardous gas releases. A method for toxic gas leak simulation and control effectiveness assessment was described in this report. Simulation of a gas leak was obtained using known amounts of sulfur-hexafluoride (SF6) tracer gas. Electron capture gas chromatography was used to analyze the surrounding atmospheres. Worst case scenarios were achieved by SF6 tracer gas being released at the same delivery pressure as in the hazardous gas line. The tracer gas delivery tubing was routed into the hazardous gas secondary containment. Air samples were taken from the workroom air immediately surrounding the secondary enclosure. The samples were taken at 1, 3, and 5 minutes following the release of the tracer gas. If no SF6 greater than background was detected in the air samples, secondary containment integrity was verified to a level of less than 100 parts per trillion hazardous gas contamination of work room air. Additional discussion was given to determining the best location for the gas detector sensor, cleaning rates, contamination recirculation, environmental testing, primary containment leak testing, and exhaust air flow determination. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:213-225
-
NIOSHTIC Number:nn:00189067
-
Citation:Hazard Assessment and Control Technology in Semiconductor Manufacturing, Lewis Publishers, Inc., Chelsea, Michigan 1989:213-225
-
Federal Fiscal Year:1989
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:Hazard Assessment and Control Technology in Semiconductor Manufacturing, Lewis Publishers, Inc., Chelsea, Michigan
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like