Fourier Transform Infrared Spectroscopic Methods for Industrial Hygiene Air Monitoring - II: Semiconductor Process Gasses.
Public Domain
-
1989/01/01
Details
-
Personal Author:
-
Description:A Fourier Transform Infrared (FTIR) spectrometer system with a long path gas cell was designed and tested for use in monitoring semiconductor processing areas for concentrations of hazardous materials below threshold limit levels. Two of the major concerns in this approach were the choice of the proper wavelength region for quantitation of gas and vapor mixtures and the choice of appropriate spectral resolution for rapid and accurate monitoring of the selected target analytes. The system was built to determine the resolution that would provide the optimum balance between analysis time, data storage space, accuracy of quantitation, and the ability to differentiate compounds with overlapping spectra when analyzing parts per billion levels of metal hydrides and organic vapors in simulated workplaces. Data were collected using a Nicolet 20 SXB FTIR spectrometer equipped with a liquid nitrogen cooled InSb/HgCdTe(MCT) sandwich detector. Concentrations of the gases detected ranged from 0.01 to 1.0 parts per million. Optimum spectral regions for quantitation of the study gases were listed. The authors suggest that for measuring low concentrations of arsine (7784421), phosphine (7803512), and diborane (19287457), the use of single point quantitation methods may not be appropriate due to the fact that these compounds do not appear to follow the Beer Lambert law at concentrations below part per million levels. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:259-264
-
NIOSHTIC Number:nn:00189070
-
Citation:Hazard Assessment and Control Technology in Semiconductor Manufacturing, Lewis Publishers, Inc., Chelsea, Michigan 1989:259-264
-
CAS Registry Number:
-
Federal Fiscal Year:1989
-
Peer Reviewed:False
-
Source Full Name:Hazard Assessment and Control Technology in Semiconductor Manufacturing, Lewis Publishers, Inc., Chelsea, Michigan
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like