The influence of respiratory protective devices on wearers at sub- maximum dosed work stress.
Public Domain
-
1980/09/01
Details
-
Personal Author:
-
Description:The stress of wearing a respiratory protective device was investigated. Volunteers ranging from 18 to over 51 years of age ran on a treadmill set at 2.25 kilometers per hour with an 11 percent incline. Each subject ran the treadmill wearing a compressed air breathing apparatus or filter cartridge equipment, with or without a facepiece, with or without the compressed air or cartridge. The influence of the weight of the equipment, breathing resistance, and facepiece deadspace on stress on the lungs and cardiovascular system was measured. The heartbeat frequency rose an average of three and 11 beats per minute, respectively, with the addition of a facepiece and facepiece plus cartridge, due mostly to dynamic deadspace of the facepiece. The compressed air breathing apparatus increased the rate a total of 24 beats per minute due to the weight of the apparatus. The 16 kilogram weight also increased the wearer's breathing minute volume by up to 7 liters per minute. Although no effect on breathing minute volume was observed in wearers of the cartridges, they did express discomfort due to breathing resistance. The authors propose that this type of information be considered when performance standards are set. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:299-314
-
NIOSHTIC Number:nn:00123911
-
Citation:NIOSH 1980 Sep; :299-314
-
Federal Fiscal Year:1980
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:Papers from the NIOSH International Respirator Research Workshop, September 9-11, 1980, Division of Safety Research, NIOSH, Morgantown, WV
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like