Exhalation Valve Leakage Test
Public Domain
-
1976/02/01
-
By McGinnis NJ
Details
-
Personal Author:
-
Description:A certification test procedure is described for measuring exhalation valve leakage on respirators. The equipment and method are described by which dry exhalation valves and valve seats are subjected to a suction of 25 millimeters of water. Leakage is measured with a bubble meter and must not exceed 30 milliliters per minute. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-24
-
NIOSHTIC Number:nn:00054469
-
NTIS Accession Number:PB-252692
-
Citation:NIOSH 1976 Feb; :1-24
-
Federal Fiscal Year:1976
-
Peer Reviewed:False
-
Source Full Name:Testing and Certification Branch, Appalachian Laboratory for Occupational Safety and Health, NIOSH, Morgantown, West Virginia, Report No. TC-R-005, 24 pages, 2 references
-