Comparison of Permeation of 2-Butoxyethanol Through Single and Multiple Layers of Disposable Nitrile Gloves
-
2017/06/20
-
By Song EJ
Details
-
Personal Author:
-
Description:The hypothesis was that multiple layers of disposable nitrile gloves would protect longer against 2-butoxyethanol (2-BE) than a single layer relative to standardized breakthrough time (SBRT) and steady state permeation rate (SSPR). Many industries such as aerospace, automotive, recycling, and waste disposal facilities utilize 2-BE. The resistance of disposable blue powder- free nitrile gloves (Kimberly-Clark) against 2-BE was tested in single, double, and triple layers. The American Society for Testing and Materials (ASTM) Method F739-12 for permeation resistance under continuous contact was used. For each run set, four 1-inch diameter permeation cells (three cells with 10 mL 2-BE as challenge and one air blank (1)) were used with 10 mL deionized water as the collection solvent in a water bath shaken at 72.3 +/- 0.58 revolution/minute (4.82 +/- 0.04 cm/second) at 35.0 +/- 0.5 degrees C. 0.1 mL aliquots were sampled at 5, 10, 20, 30, 40, 50, 135, 240, 360, and 480 minutes. Capillary column gas chromatography-mass spectrometry (GC- MS) utilized mass to charge ratios 2-BE at m/z= 57 and 87, and 4-bromophenol (4-BP) internal standard at m/z= 174 (1). The retention times for 2-BE and 4-BP were 4.8 min and 7.9 min. SBRT were found between 5 to 10 minutes for single, between 10 to 20 minutes for double, and between 30 to 40 minutes for triple layers, though thus not statistically different at p ≤ 0.050. Single gloving had a rating of 'poor,' while double and triple gloving were 'good,' based on Kimberly Clark Professional permeation breakthrough time criteria. The other statistically different comparison was for the mass/area permeation at 30 minutes for the triple layer relative to a single layer. The average SSPR were 41.20 +/- 8.81 ug/cm2/min for single gloving, 48.48 +/- 55.57 ug/cm2/min for double gloving, and 5.39 +/- 4.64 ug/cm2/min for triple gloving. Both single and double gloving had a rating of good, and triple gloving had a rating of very good based on Ansell permeation rate criteria for Chemical Resistant Gloves. Thus, multiple layers did tend to prolong SBRT, but only triple layers definitely lowered the SSPR. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-24
-
NIOSHTIC Number:nn:20055875
-
Citation:Los Angeles, CA: University of California, 2017 Jun; :1-24
-
CAS Registry Number:
-
Federal Fiscal Year:2017
-
Performing Organization:University of California Los Angeles
-
Peer Reviewed:True
-
Start Date:20050701
-
Source Full Name:Comparison of permeation of 2-butoxyethanol through single and multiple layers of disposable nitrile gloves
-
End Date:20270630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:091d6c7b6a94605204e8f8704e862e2348991ea4295f38eb0c2aa05b85db4ba70f4345f7e1d25f4b6f0b0955bc7b1cfd1f7368d00ee0376650286672eef3c58b
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like