Evaluation of pulmonary and systemic toxicity of oil dispersant (COREXIT EC9500A®) following acute repeated inhalation exposure
Public Domain
-
2015/02/09
-
Details
-
Personal Author:
-
Description:Introduction: Oil spill cleanup workers come into contact with numerous potentially hazardous chemicals derived from the oil spills, as well as chemicals applied for mitigation of the spill, including oil dispersants. In response to the Deepwater Horizon Macondo well oil spill in the Gulf of Mexico in 2010, a record volume of the oil dispersant, COREXIT EC9500A, was delivered via aerial applications, raising concern regarding potential health effects that may result from pulmonary exposure to the dispersant. Methods: The current study examined the effects on pulmonary functions, cardiovascular functions, and systemic immune responses in rats to acute repeated inhalation exposure of COREXIT EC9500A at 25 mg/m3, five hours per day, over nine work days, or filtered air (control). At one and seven days following the last exposure, a battery of parameters was measured to evaluate lung function, injury, and inflammation; cardiovascular function; peripheral vascular responses; and systemic immune responses. Results: No significant alterations in airway reactivity were observed at one or seven days after exposure either in baseline values or following metha-choline (MCh) inhalation challenge. Although there was a trend for an increase in lung neutrophils and phagocyte oxidant production at one-day post exposure, there were no significant differences in parameters of lung inflammation. In addition, increased blood monocytes and neutrophils, and decreased lymphocyte numbers at one-day post exposure also did not differ significantly from air controls, and no alterations in splenocyte populations, or serum or spleen immunoglobulin M (IgM) to antigen were observed. There were no significant differences in peripheral vascular responsiveness to vasoconstrictor and vasodilator agonists or in blood pressure (BP) responses to these agents; however, the baseline heart rate (HR) and HR responses to isoproterenol (ISO) were significantly elevated at one-day post exposure, with resolution by day 7. Conclusions: In summary, acute repeated exposure to COREXIT EC9500A did not alter pulmonary function, lung injury/inflammation, systemic immune responses, or vascular tone, but did cause transient chronotropic effects on cardiac function. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1178-6302
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:63-64
-
Volume:8
-
NIOSHTIC Number:nn:20045711
-
Citation:Environ Health Insights 2015 Feb; 8(Suppl 1):63-74
-
Email:jur6@cdc.gov
-
Federal Fiscal Year:2015
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Environmental Health Insights
-
Supplement:1
-
Collection(s):
-
Main Document Checksum:urn:sha-512:c3c18de1fd8f18e7cc062dc3d66ad9386be6194f4d51a71f444ec4a7fa9dc02ceacc962e2a8e88965f88247dbcbb86982bfeaf9c9b9151d99c31efd2afc8acad
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like