A novel immunochromatographic electrochemical biosensor for highly sensitive and selective detection of trichloropyridinol, a biomarker of exposure to chlorpyrifos
-
2011/02/15
Details
-
Personal Author:
-
Description:We present a novel portable immunochromatographic electrochemical biosensor (IEB) for simple, rapid, and sensitive biomonitoring of trichloropyridinol (TCP), a metabolite biomarker of exposure to organophosphorus insecticides. Our new approach takes the advantage of immunochromatographic test strip for a rapid competitive immunoreaction and a disposable screen-printed carbon electrode for a rapid and sensitive electrochemical analysis of captured HRP labeling. Several key experimental parameters (e.g. immunoreaction time, the amount of HRP labeled TCP, concentration of the substrate for electrochemical measurements, and the blocking agents for the nitrocellulose membrane) were optimized to achieve a high sensitivity, selectivity and stability. Under optimal conditions, the IEB has demonstrated a wide linear range (0.1-100 ng/ml) with a detection limit as low as 0.1 ng/ml TCP. Furthermore, the IEB has been successfully applied for biomonitoring of TCP in the rat plasma samples with in vivo exposure to organophosphorus insecticides like Chlorpyrifos-oxon (CPF-oxon). The IEB thus opens up new pathways for designing a simple, rapid, clinically accurate, and quantitative tool for TCP detection, as well as holds a great promise for in-field screening of metabolite biomarkers, e.g., TCP, for humans exposed to organophosphorus insecticides. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0956-5663
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:26
-
Issue:6
-
NIOSHTIC Number:nn:20038748
-
Citation:Biosens Bioelectron 2011 Feb; 26(6):2835-2840
-
CAS Registry Number:
-
Federal Fiscal Year:2011
-
NORA Priority Area:
-
Performing Organization:Battelle Pacific Northwest Laboratories
-
Peer Reviewed:True
-
Start Date:20060901
-
Source Full Name:Biosensors and Bioelectronics
-
End Date:20170831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:729811fe55e974d03a93ff0df07133d549c13450102821cb8012d37a765be0ec72dc3c5ac74e3492c8d36fe97f03386961a34c4b9c91b426259f83f6699f3eb7
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like