Application of computed radiography for the diagnosis of pneumoconioses.
Public Domain
-
1990/09/01
-
Details
-
Personal Author:Chiba Y ; Fukuhisa K ; Hosoda Y ; Iinuma T ; Kato H ; Kobatake H ; Matsumoto T ; Nobechi T ; Shida H ; Tachi M ; Takano M ; Tateno Y ; Toriwaki J
-
Description:Experiments were carried out to determine the application of computer radiography for the diagnosis of cases of pneumoconiosis. For two of the experiments the International Labor Office (ILO) Standard films and test films selected from training films of pneumoconioses in the United States were digitized by using a drum scanner. In another of the experiments the Fuji Computed Radiography (FCR) films of pneumoconioses patients were used with the fixed contrast of 0.85 gamma with several spacial frequency characteristics. Magnetic tapes of the digitized images of ILO standard film and test films and FCR were used for the evaluation of the automatic determination of the size and profusion of small rounded opacities. Two methods were used for this purpose. The one was a direct detection method using difference linear filtering and the other was a texture analysis method. It was apparently easy to determine the size and various other parameters, while the automatic categorization of the profusion was not so easy for the low profusion groups, although various methods disclosed an accuracy of 45 to 71%. The authors conclude that the results of these experiments are promising for the future application of computer technique for the automatic diagnosis of pneumoconioses.
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:495-496
-
NIOSHTIC Number:nn:00198450
-
Citation:Proceedings of the VIIth International Pneumoconioses Conference, August 23-26, 1988, Pittsburgh, Pennsylvania, USA. Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 90-108, 1990 Sep; (Part I):495-496
-
Federal Fiscal Year:1990
-
Peer Reviewed:False
-
Part Number:I
-
Source Full Name:Proceedings of the VIIth International Pneumoconioses Conference, August 23-26, 1988, Pittsburgh, Pennsylvania, USA
-
Collection(s):
-
Main Document Checksum:urn:sha-512:0383f170124514a7a315d51b5ba860796743d06d4c18f399794700364f179546b053f1bd9c44c8a579b52b80de924c6151baa5b045f40a9a50c5cfab3a8e29da
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like