Control of exposure to perchloroethylene in commercial drycleaning (ventilation)
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates
...

to

...
Document Data
Library
People
Clear All
...
Clear All

For additional assistance using the Custom Query please check out our Help Page

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners. As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i

Control of exposure to perchloroethylene in commercial drycleaning (ventilation)




Details:

  • Personal Author:
  • Corporate Authors:
  • Description:
    "The control of perchloroethylene (127184) (PERC) exposure in commercial dry cleaning through ventilation was reviewed. Health hazards associated with PERC included central nervous system depression, liver and kidney damage, memory impairment, dermatitis, respiratory irritation, and other symptoms. Effective ventilation was considered to be one of the least expensive engineering measures for reducing worker exposures to PERC. Ventilation was used for controlling PERC exposures and thermal comfort, both of which were important in dry cleaning shops. Possible ventilation methods included local exhaust ventilation and general ventilation. Local exhaust ventilation (LEV) captured and removed the contaminant at or near the source of release, thereby reducing vapor levels in the worker's breathing zone and minimizing vapor diffusion. PERC vapor exposures were greatest during machine maintenance and loading and unloading. LEV implemented at the loading and unloading door was usually activated by a door interlocking system. The retrofitting of an external ventilation hood outside the machine door was an option for older machines lacking built in exhaust ventilation. General ventilation diluted the concentration of the contaminant before it reached the breathing zone of the worker. It was used to supply conditioned fresh air and exhaust contaminated air from the general work area. A workroom air exchange every 5 minutes involving sufficient volumes of make up air was recommended. Systems of emergency ventilation were needed to control solvent vapors resulting from solvent spills or leaks." - NIOSHTIC-2
  • Content Notes:
    [principal contributors, Gary S. Earnest, Charles S. Hayden, Daniel S. Watkins, Rosmarie T. Hagedorn, and Jerome P. Flesch.].
  • Subjects:
  • Series:
  • Subseries:
  • Document Type:
  • Place as Subject:
  • Pages in Document:
    print; 4 leaves : ill. ; 28 cm.
  • Resource Number:
    Hazard controls ; HC 19;DHHS publication ; no. (NIOSH) 97-157;
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:
    Filetype[PDF-103.65 KB]

Related Documents

You May Also Like

Checkout today's featured content at stacks.cdc.gov