Accuracy and precision of microseismic event locations in rock burst research studies
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners. As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i

Accuracy and precision of microseismic event locations in rock burst research studies

Filetype[PDF-3.94 MB]


English

Details:

  • Personal Author:
  • Corporate Authors:
  • Description:
    "Stability analyses of fractured and faulted rock masses require delineation of the position, extent, and orientation of geologic discontinuities. The size of the smallest active discontinuity that may potentially be resolved using the spatial distribution of microseismic event locations is limited by the accuracy and precision of the location methods. At a hard-rock mine in Coeur d'Alene mining district of northern Idaho, two data sets consisting of calibration blast signals from a known source site and origin time and microseismic event signals were recorded using a stopewide accelerometer array. These seismic signals are used to quantify various sources of error in event location. Five factors influencing source location errors are examined in this U.S. Bureau of Mines study: (1) biases of the numerical source location techniques, (2) receiver array geometries, (3) uncertainties in receiver positions, (4) errors in picking arrival times, and (5) uncertainties in seismic velocity structure, including the effect of mine openings. In addition, synthetic data (accelerometer positions, travel-time picks, and wave velocity) are used to determine the effect of known systematic and random errors on source location calculations. It is shown that the commonly accepted association of minimum travel-time residuals with the best location solution does not necessarily hold true when there is a systematic error in seismic velocity. Recommendations are made for increasing the accuracy and precision of locations of mircoseismic events detected under similar field conditions." - NIOSHTIC-2

    NIOSHTIC no. 10011113

  • Subjects:
  • Series:
  • Subseries:
  • Document Type:
  • Genre:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    ii, 40 numbered pages
  • NIOSHTIC Number:
    nn:10011113
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at stacks.cdc.gov