Technical Bulletin - Pager Phones: Installation; USBM Contract No. S0241032
  • Published Date:
    1/4/1975
Filetype[PDF-438.19 KB]


Details:
  • Description:
    INTRODUCTION The pager phones used in many underground coal mines are battery- operated, party-line telephones with provisions for loudspeaker paging. The system is two-wire, non-polarized, and is operated by self-contained batteries. Many of the individual units are certified as permissible. Requirements for installation are specified in state and federal regulations, such as in the Code of Federal Regulations, Title 30, Mineral Resources, Part 75. The major federal regulations that affect communication in coal mines are noted below, with a brief description of the subject matter in each of the relevant paragraphs. Refer to the cited paragraphs of Title 30 for explicit details of these regulations. (This brief description is for reference purposes only.) Minimum Requirements (paragraphs 75.1600, 75.17 13-2, and 75.1003-1) Approved telephone or two-way communication will be provided between the surface and each main shaft landing and each working section ; to the nearest medical assistance; and shall be protected from contact with trolley wires or trolley feeder wires. Installation Requirements (paragraphs 75.5 16-2, 75.52 1, and 77.508-1 ) Communication wires will be supported on insulated hangers, attached to messenger cables, or buried, to protect against mechanical damage ; installed opposite trolley wires; and insulated near power conductors . . . each cable will have lightning arresters within 100 feet of going below ground . . . and arresters will be provided wherever telephone wires enter a building. Wire and Cable Requirements (paragraphs 75.5 16-2, 75.5 17, and 75.52 1) Communication cable means two or more insulated conductors, covered by an additional abrasion-resistant covering; power wires and cables shall be adequately insulated and fully protected; and lightning arresters shall be connected to low-resistance grounds, more than 25 feet from neutral grounds.

  • Supporting Files:
    No Additional Files
No Related Documents.
You May Also Like: