Use of a Test Box to Measure Response Times for Machine-Mounted Monitors
  • Published Date:
    0/1/1900
Filetype[PDF-240.19 KB]


Details:
  • Description:
    A technique for use in underground coal mines measures the response times of machine-mounted methane monitors. This technique uses a calibration cup to deliver gas to the sensor head to measure response times. For comparison, in the current study, response times were measured by placing methane sensor heads in a specially designed test box where they were exposed to an atmosphere containing a constant concentration of methane. Response time readings measured in the test box were shorter than the readings obtained using the calibration cup. The response times measured in the test box were comparable for sensors from three different manufacturers. The effects of dust cap and flame arrestor design on response times were also evaluated using the test box.