Bleederless ventilation systems as a spontaneous combustion control measure in U.S. coal mines
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Bleederless ventilation systems as a spontaneous combustion control measure in U.S. coal mines

Filetype[PDF-3.08 MB]


  • English

  • Details:

    • Personal Author:
    • Description:
      "The U.S. Bureau of Mines conducted a worldwide literature review of bleederless ventilation practices to evaluate their use as a spontaneous combustion control measure in U.S. coal mines. Factors that must be taken into account in the design and use of these systems include seal construction, the use of ventilation control devices, the use of methane-drainage systems in gassy mines, and the ground control plan. Monitoring for the detection of spontaneous combustion and the control of methane when methane-drainage techniques are employed is critical to the successful use of a bleederless ventilation system. This report describes the types of ventilation systems used throughout the world and the spontaneous combustion risks associated with these systems. Methane-drainage systems used in conjunction with bleederless ventilation systems are discussed. Ground control considerations such as pillar design, entry stability, and seal usage are reviewed. Monitoring systems for spontaneous combustion detection, methane-drainage control, and behind seals are examined. Finally, methods for evaluating the spontaneous combustion hazard of a mining operation to determine when the use of a bleederless ventilation system is warranted are reviewed." - NIOSHTIC-2

      NIOSHTIC no. 10004943

    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov