Welcome to CDC Stacks | Self-Contained Self-Rescuer Field Evaluation: Seventh-Phase Results - 8325 | National Institute for Occupational Safety and Health
Stacks Logo
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.
 
 
Help
Clear All Simple Search
Advanced Search
Self-Contained Self-Rescuer Field Evaluation: Seventh-Phase Results
  • Published Date:
    3/1/2002
Filetype[PDF - 2.42 MB]


Details:
  • Description:
    The National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, has undertaken a study to determine how well self-contained self-rescuers (SCSRs), deployed in accordance with Federal regulations (30 CFR 75.1714), hold up in the underground environment with regard to both physical damage and aging. This report presents findings regarding laboratory-tested SCSRs in the seventh phase of testing from May 1999 to August 2000. The SCSRs were tested on human subjects and on a breathing and metabolic simulator. The results indicate that most of the apparatus, if they pass their approved inspection criteria, perform satisfactorily. The deployed CSE SR-100s, however, exhibited significantly higher inhaled carbon dioxide (CO2) levels than new units, as they did in the previous two phases. Several Draeger OXY K-Pluses that rattled when shaken were found to have potassium superoxide (KO2) particles throughout the breathing circuit, including the mouthpiece. Draeger investigated the problem and developed a shake test to detect damaged units. The durations of new Ocenco M-20s were statistically significantly longer than those of deployed units, although only by 2 min.

  • Supporting Files:
    No Additional Files