A Performance evaluation of two overhead power line proximity warning devices

Filetype[PDF-24.15 MB]


Select the Download button to view the document
This document is over 5mb in size and cannot be previewed

Details:

  • Personal Author:
  • Corporate Authors:
  • Description:
    Accidental contact of overhead electrical power lines by mobile equipment is a leading cause of occupational fatalities in the United States, accounting for 20% of on-the-job electrocutions. Overhead electrical power line proximity warning devices (PWDs) are intended to warn personnel if mobile equipment moves within some preselected minimum distance of an energized overhead electrical power line. Two commercially available PWDs were tested at the National Institute for Occupational Safety and Health's (NIOSH) Pittsburgh Research Laboratory (PRL). The objective of the tests was to document performance capabilities and limitations for these PWDs by identifying factors that can influence their operation. The two PWDs evaluated in this research are the SIGALARM Model 210 marketed by Allied Safety Systems, LLC, and the ASE Model 2100 from Allied Safety Engineering. Both of these devices operate by measuring the electric field present around energized power lines. The PWDs were installed on a government-owned 22-st (20-mt) rough terrain crane. A purpose-built test site used for this research at PRL allowed operation of the crane near a variety of power line configurations operating at up to 25 kV. Most of the tests involved positioning the crane adjacent to one or more overhead power lines, adjusting sensitivities of the PWDs to alarm when the crane boom was approximately 20 ft (6.1 m) from the power lines, swinging the crane boom toward the lines under a wide variety of test conditions, and finally, for each unique set of test conditions, documenting the deviation from 20 ft (6.1 m) for actual alarm activation. Test results show that several factors can adversely affect PWD performance. PWD alarm accuracy generally deteriorated when operating with a boom position significantly different than that used for the device's last sensitivity adjustment. Another factor that can affect PWD performance is configuration of the overhead power line(s) involved. Accuracy of alarm activation distances was best for simple single-circuit installations, but degraded for multiple circuits on the same poles. This degradation was slightly greater for installations with different voltage levels and/or a combination of vertical and horizontal conductor arrangements. Performance also degraded for crane operation between two intersecting power line installations, especially for intersecting lines at different voltages. An additional aspect of power line configuration shown to influence PWD accuracy was phase sequence on the power line circuit(s). Specific phase conductor arrangements and combinations, particularly in multiple circuit installations, resulted in either improved or degraded accuracy. Tests were also conducted to evaluate the PWDs as "early warning devices" for situations such as moving a mobile crane into an unfamiliar work area. Results showed that the SIGALARM Model 210 could detect energized 13-kV power lines at a distance of 75-88 ft (22.9-26.8 m). This alarm distance would allow an operator to take preventive measures before the crane is in a position from which it could contact nearby power lines.

    NIOSHTIC No 20034865

  • Content Notes:
    by Gerald T. Homce, James C. Cawley, and Michael R. Yenchek.

    "November 2008."

    "CDC workplace safety and health"--Cover.

    Also available via the World Wide Web.

    Includes bibliographical references (p. 36).

  • Subjects:
  • Series:
  • Subseries:
  • DOI:
  • Document Type:
  • Pages in Document:
    print; 37 p. : ill. ; 28 cm.
  • NIOSHTIC Number:
    20034865
  • Resource Number:
    DHHS (NIOSH) Publication No. 2009-110; IC-9510