Bacteria in a water-damaged building: associations of actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Bacteria in a water-damaged building: associations of actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants

Filetype[PDF-348.30 KB]



Details:

  • Alternative Title:
    Indoor Air
  • Description:
    We examined microbial correlates of health outcomes in building occupants with a sarcoidosis cluster and excess asthma. We offered employees a questionnaire and pulmonary function testing and collected floor dust and liquid/sludge from drain tubing traps of heat pumps that were analyzed for various microbial agents. Forty-nine percent of participants reported any symptom reflecting possible granulomatous disease (shortness of breath on exertion, flu-like achiness, or fever and chills) weekly in the last 4 weeks. In multivariate regressions, thermophilic actinomycetes (median = 529 CFU/m2 ) in dust were associated with FEV1 /FVC [coefficient = -2.8 per interquartile range change, P = 0.02], percent predicted FEF25-75% (coefficient = -12.9, P = 0.01), and any granulomatous disease-like symptom [odds ratio (OR) = 3.1, 95% confidence interval (CI) = 1.45-6.73]. Mycobacteria (median = 658 CFU/m2 ) were positively associated with asthma symptoms (OR = 1.5, 95% CI = 0.97-2.43). Composite score (median = 11.5) of total bacteria from heat pumps was negatively associated with asthma (0.8, 0.71-1.00) and positively associated with FEV1 /FVC (coefficient = 0.44, P = 0.095). Endotoxin (median score = 12.0) was negatively associated with two or more granulomatous disease-like symptoms (OR = 0.8, 95% CI = 0.67-0.98) and asthma (0.8, 0.67-0.96). Fungi or (1→3)-β-D-glucan in dust or heat pump traps was not associated with any health outcomes. Thermophilic actinomycetes and non-tuberculous mycobacteria may have played a role in the occupants' respiratory outcomes in this water-damaged building.
  • Pubmed ID:
    26717439
  • Pubmed Central ID:
    PMC5035226
  • Document Type:
  • Collection(s):
  • Main Document Checksum:
  • File Type:

You May Also Like

Checkout today's featured content at stacks.cdc.gov