Bacteria in a water-damaged building: associations of actinomycetes and non-tuberculous mycobacteria with respiratory health in occupants
Public Domain
-
2017/01/01
-
Details
-
Personal Author:
-
Description:We examined microbial correlates of health outcomes in building occupants with a sarcoidosis cluster and excess asthma. We offered employees a questionnaire and pulmonary function testing and collected floor dust and liquid/sludge from drain tubing traps of heat pumps that were analyzed for various microbial agents. Forty-nine percent of participants reported any symptom reflecting possible granulomatous disease (shortness of breath on exertion, flu-like achiness, or fever and chills) weekly in the last 4 weeks. In multivariate regressions, thermophilic actinomycetes (median=529 CFU/m2) in dust were associated with FEV1/FVC [coefficient=-2.8 per inter-quartile range change, p=0.02], percent predicted FEF(25-75%) (coefficient=-12.9, p=0.01), and any granulomatous disease-like symptom [odds ratio (OR)=3.1, 95% confidence interval (CI)=1.45-6.73]. Mycobacteria (median=658 CFU/m2) were positively associated with asthma symptoms (OR=1.5, 95% CI=0.97-2.43). Composite score (median=11.5) of total bacteria from heat pumps was negatively associated with asthma (0.8, 0.71-1.00) and positively associated with FEV1/FVC (coefficient=0.44, p=0.095). Endotoxin (median score=12.0) was negatively associated with two or more granulomatous disease-like symptoms (OR=0.8, 95% CI=0.67-0.98) and asthma (0.8, 0.67-0.96). Fungi or (1 -->3)-beta-D-glucan in dust or heat pump traps were not associated with any health outcomes. Thermophilic actinomycetes and nontuberculous mycobacteria may have played a role in the occupants' respiratory outcomes in this water-damaged building. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0905-6947
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:24-33
-
Volume:27
-
Issue:1
-
NIOSHTIC Number:nn:20047254
-
Citation:Indoor Air 2017 Jan; 27(1):24-33
-
Contact Point Address:Dr. Ju-Hyeong Park, Division of Respiratory Disease Studies, National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, WV 26505
-
Email:gzp8@cdc.gov
-
Federal Fiscal Year:2017
-
Peer Reviewed:True
-
Source Full Name:Indoor Air
-
Collection(s):
-
Main Document Checksum:urn:sha-512:205125d9c00fc509ae4743aaa926f2fd381a68888f54a7e9de6e821444299fb95ae7b66d0336bc66071431e39d0398968bbfb0d1c2f4be95f284dc5de2f6370f
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like