Decontamination of Targeted Pathogens from Patient Rooms Using an Automated Ultraviolet-C-Emitting Device
Filetype[PDF - 198.83 KB]


Details:
  • Corporate Authors:
    CDC Prevention Epicenters Program
  • Funding:
    K23 AI095357/AI/NIAID NIH HHS/United States
    K23AI095357/AI/NIAID NIH HHS/United States
    U54CK000164/CK/NCEZID CDC HHS/United States
  • Document Type:
  • Collection(s):
  • Description:
    OBJECTIVE

    To determine the effectiveness of an automated ultraviolet-C (UV-C) emitter against vancomycin-resistant enterococci (VRE), Clostridium difficile, and Acinetobacter spp. in patient rooms.

    DESIGN

    Prospective cohort study.

    SETTING

    Two tertiary care hospitals.

    PARTICIPANTS

    Convenience sample of 39 patient rooms from which a patient infected or colonized with 1 of the 3 targeted pathogens had been discharged.

    INTERVENTION

    Environmental sites were cultured before and after use of an automated UV-C-emitting device in targeted rooms but before standard terminal room disinfection by environmental services.

    RESULTS

    In total, 142 samples were obtained from 27 rooms of patients who were colonized or infected with VRE, 77 samples were obtained from 10 rooms of patients with C. difficile infection, and 10 samples were obtained from 2 rooms of patients with infections due to Acinetobacter. Use of an automated UV-C-emitting device led to a significant decrease in the total number of colony-forming units (CFUs) of any type of organism (1.07 log10 reduction; P < .0001), CFUs of target pathogens (1.35 log10 reduction; P < .0001), VRE CFUs (1.68 log10 reduction; P < .0001), and C. difficile CFUs (1.16 log10 reduction; P < .0001). CFUs of Acinetobacter also decreased (1.71 log10 reduction), but the trend was not statistically significant (P = .25). CFUs were reduced at all 9 of the environmental sites tested. Reductions similarly occurred in direct and indirect line of sight.

    CONCLUSIONS

    Our data confirm that automated UV-C-emitting devices can decrease the bioburden of important pathogens in real-world settings such as hospital rooms.