U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Development of a Flow Imaging Microscopy-Based Method for Rapid and High-Throughput Measurement of Fiber Count and Length Distributions

Public Domain
File Language:
English


Details

  • Personal Author:
  • Description:
    Measurement of the distribution of airborne fiber length and number count in an air sample is important to assess exposures to asbestos and elongated mineral particles (EMPs) in workplace atmospheres. Exposure to noncommercial EMPs with the potential for asbestos-like health effects is an emerging issue. Phase contrast microscopy (PCM; NIOSH method 7400) is commonly used for assessing inhalation exposure to airborne asbestos or other EMPs; however, the method is labor- and time-intensive, especially for dilute samples. In addition, PCM lacks the capability to accurately count, size, and identify all fibers collected on filters with robust counting statistics. In this study, a flow imaging microscopy (FIM) method was investigated for measurement of number and fiber length distribution. First, monodisperse polystyrene latex count and size standards with microspheres in the diameter range of 2 µm -70 µm were used to examine counting and sizing accuracies of the FIM method, with objective lens magnifications of 4X and 10X for spherical particles. Then, test glass fibers were either i) prepared as a suspension in deionized water from bulk fiber powder or were ii) aerosolized by vortex shaking of glass fiber powder and collected on cascade mesh micro-screens with different pore sizes to obtain fiber samples with different lengths. Sizing accuracy of the FIM for spherical particles was verified in the range 5-70 µm with less than 13 % and 3 % difference for 4X and 10X, respectively. FIM measurement of fiber length distributions with 10X for geometric mean lengths in the range of 14.0 to 20.0 µm was in reasonable agreement with the PCM, resulting in about a 12.4.% difference. The study demonstrates that the high-throughput measurement capability of FIM shows promise for conducting fiber analysis of workplace air samples at significantly reduced time and/or cost and robust counting statistics. Description provided by NIOSH
  • Subjects:
  • Keywords:
  • Source:
    Abstracts from the AAAR 42nd Annual Conference, October 21-25, 2024, Albuquerque, New Mexico. Reston, VA: American Association for Aerosol Research, 2024 Oct; :180
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    1 pdf page
  • NIOSHTIC Number:
    nn:20071697
  • Federal Fiscal Year:
    2025
  • Peer Reviewed:
    False
  • Download URL:
  • File Type:
    Filetype[PDF - 650.69 KB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:fd09825622b63bf5ab58fe5fe05601c17f91bfb12bf35f3adb3435e6b8180fc635fce65f06880bc81c369801f7b200b057d4b7efbc5968c7d843e4db0bcd42aa
File Language:
English
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.