Development of forced random noise system for the measurement of respiratory impedance. Final Report.
Public Domain
-
1983/12/01
-
Details
-
Personal Author:
-
Description:Part one of the study called for the design and analysis of a respiratory measurement system employing forced random noise. Respiratory impedance of a human was determined by the administration of a noninvasive test in which random oscillations were superimposed on the respiratory cycle. Spectral analysis was applied to the forcing pressure and resultant flow to arrive at a measure of impedance which is a function of frequency. The measuring system consisted of a random noise source, speaker enclosure, and a portable computer. To isolate physiological (ZL) and respiratory (Zrsp) impedance from measured data, the impedance contributions of the system were determined. With this system, ZL could be determined in less than five minutes with Zrsp isolation taking twice the time. The magnitude and phase of Zrsp for a normal healthy adult were comparable to the results obtained by other studies. In part two of the study lung function responses to inhaled cotton dust were evaluated in a group of 58 healthy subjects by spirometry (MEFV curves) and forced random noise impedance parameters. The data indicate that measures of the Thevenin resistance (real part of impedance) by the forced random noise method are reliable indicators of cotton induced bronchoconstriction. However, measurement variability suggests that these are more appropriate for group studies and should remain adjuncts to standard tests of lung function such as spirometry. [Description provided by NIOSH]
-
Content Notes:in NTRL, no PDF
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-161
-
NIOSHTIC Number:nn:00163312
-
NTIS Accession Number:PB86240439
-
Citation:NIOSH 1983 Dec; :1-161
-
Federal Fiscal Year:1984
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:Division of Respiratory Disease Studies, NIOSH, Morgantown, West Virginia
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like