The Effect of Toe Marker Placement Error on Joint Kinematics and Muscle Forces Using OpenSim Gait Simulation

Peer Reviewed


Details

  • Personal Author:
  • Description:
    Marker placement can be a significant source of error in biomechanical studies of human movement. The toe marker placement error is amplified by footwear since the toe marker placement on the shoe only relies on an approximation of underlying anatomical landmarks. Three total knee replacement subjects were recruited and three self-speed gait trials per subject were collected. The height variation between toe and heel markers of four types of footwear was evaluated from the results of joint kinematics and muscle forces using OpenSim. The reference condition was considered as the same vertical height of toe and heel markers. The results showed that the residual variances for joint kinematics had an approximately linear relationship with toe marker placement error for lower limb joints. Ankle dorsiflexion/plantarflexion is most sensitive to toe marker placement error. The influence of toe marker placement error is generally larger for hip flexion/extension and rotation than hip abduction/adduction and knee flexion/extension. The muscle forces responded to the residual variance of joint kinematics to various degrees based on the muscle function for specific joint kinematics. This study demonstrates the importance of evaluating marker error for joint kinematics and muscle forces when explaining relative clinical gait analysis and treatment intervention. Description provided by NIOSH
  • Subjects:
  • Keywords:
  • ISSN:
    0959-2989
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    26
  • NIOSHTIC Number:
    nn:20067365
  • Citation:
    Biomed Mater Eng 2015 Aug; 26(S1):S685-S691
  • Contact Point Address:
    Hang Xu, Department of Medical Imaging, Xuzhou Medical College, 209 Tongshan Road, Xuzhou, P.R. China
  • Email:
    h_xu@xzmc.edu.cn
  • Federal Fiscal Year:
    2015
  • Performing Organization:
    University of Utah
  • Peer Reviewed:
    True
  • Start Date:
    20050701
  • Source Full Name:
    Bio-Medical Materials and Engineering
  • End Date:
    20280630
  • Download URL:
  • File Type:
    Filetype[PDF - 603.50 KB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:e8a2d60784b34f3774381779eb92205d38d1dc5e40f43a6651b66ab3faffb78a9983aefe4f05f6889111d03bac3a2b15cf6695f3324df15de57abd1af82b73ec
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.