Description:Background: Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance. Methods: Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels. Results: Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas. Conclusions: The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0196-6553
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:51
-
Issue:12
-
NIOSHTIC Number:nn:20068463
-
Citation:Am J Infect Control 2023 Dec; 51(12):1401-1405
-
Contact Point Address:F. Selcen Kilinc-Balci PhD, US Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA
-
Email:jcq8@cdc.gov
-
Federal Fiscal Year:2024
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:American Journal of Infection Control
-
Collection(s):
-
Main Document Checksum:urn:sha-512:cef275adb0f938a12780907d4de00f3f388e596d46597bba35d240c511d93370b5803dac2b4917441043dc03e51250669a80f7e1b87e08017ef9804f1953ca2e
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like