Construction Injury Narrative: Apprentice Electrician Suffers Arc Flash Burns [2021]
-
2021/09/13
File Language:
English
Details
-
Corporate Authors:
-
Description:An apprentice electrician suffered severe arc flash burns to his hands and face while attempting to install a breaker into an energized electrical panel. The apprentice had worked for his employer, an electrical contractor, for three years. The plan was for the apprentice to install the breaker into the 600amp/480volt main distribution panel (MDP) while his journey-level electrician coworker stood behind him supervising. They did not de-energize the panel before starting the job because they believed it was not required. Also, the customer was not required to have a disconnect ahead of the panel. The nearest disconnect was off site at the public utility transformer. They had done similar jobs in the past, and this panel had been previously inspected and approved by an electrical inspector. The apprentice was in the process of removing the heat shrink from the panel hardware when his side cutters slipped and contacted the b and c phases simultaneously, causing the line to fault. He suffered severe arc flash burns to his face and hands. He was not wearing arc flash protective clothing, gloves, or a face shield and his side cutters were not insulated. His coworker rushed him to the hospital. Investigators found: 1) A hazard assessment had not been done prior to starting the task. 2) The employer was unaware of the requirement to de-energize the panel before working on it. 3) The employer did not provide and ensure the apprentice used the proper personal protective equipment PPE). 4) The employer had their electrical installations inspected several times previously but had never been inspected for safe work practices. REQUIREMENTS-Employers must: 1. Not permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means. 3. Provide and ensure workers use appropriate PPE for electrical work. 4. Train electricians in the electrical safety work practices for construction and general industry. RECOMMENDATIONS-FACE investigators concluded that, to help prevent similar occurrences: 1. Before beginning a job, take steps to control hazardous energy instead of relying on work experience to protect workers. Always de-energize equipment and panels when possible before starting work. 2. Always use appropriate tools and PPE when working on electrical equipment, even when systems are de-energized. Description provided by NIOSH
-
Subjects:
-
Keywords:
-
Series:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1
-
NIOSHTIC Number:nn:20063486
-
Citation:Olympia, WA: Washington State Department of Labor and Industries, 71-209-2021, 2021 Sep; :1
-
Federal Fiscal Year:2021
-
Performing Organization:Washington State Department of Labor and Industries
-
Peer Reviewed:False
-
Start Date:20050701
-
End Date:20260630
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d7546b7ffdef33f4ff18d6159cf16f6df5821fda612efeea1ec36a16e5bbacb197b3072e04d5212a862055b7efe84db1cd89a25e5c4482fcfd9dbecc90e523c7
File Language:
English
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like