Evaluation of Four Portable Cooling Vests for Workers Wearing Gas Extraction Coveralls in Hot Environments
-
2013/03/06
-
By Johnson JK
Details
-
Personal Author:
-
Description:Excessive exposure to heat stress can cause a host of heat-related illnesses. For laborers, job specific work demands and protective garments greatly increase the risk of succumbing to the effects of heat stress. Microclimate cooling has been used to control heat stress exposure where administrative or engineering controls are not adequate. This study tested the performance of four personal cooling vests for use with insulated protective clothing (gas extraction coveralls) in warm-humid (35 degree C, 50% relative humidity) and hot-dry (40 degree C, 30% relative humidity) conditions. On 10 separate occasions, 5 male volunteers walked on a treadmill to elicit a target metabolic rate of 300 watts, for 120 minutes, while wearing a (a) water cooled vest, (b) air cooled vest, (c) frozen polymer vest (FP) (d) liquid CO2 cooling (LCO2) vest, or (e) no cooling (NC). A three-way mixed effects ANOVA was used to assess the results and a Tukey's Honestly Significant Difference multiple comparison test was used to identify where significant differences occurred (p < 0.05). The air, water, and FP systems produced significantly lower heat storage rates compared to NC. To the extent that the gas extraction coverall is worn in an environment between 30 degree C and 45 degree C and the rate of work is moderate, the FP, air and water vest were shown to manage heat storage well, reducing storage rate by about 48%, 56% and 65% respectively. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-44
-
NIOSHTIC Number:nn:20063774
-
Citation:Tampa, FL: University of South Florida, 2013 Mar; :1-44
-
Contact Point Address:Joseph Kevin Johnson, University of South Florida
-
Email:joekjohnson@gmail.com
-
CAS Registry Number:
-
Federal Fiscal Year:2013
-
Performing Organization:Sunshine Education and Research Center, University of South Florida
-
Peer Reviewed:False
-
Start Date:20050701
-
Source Full Name:Evaluation of four portable cooling vests for workers wearing gas extraction coveralls in hot environments
-
End Date:20290630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:932af3ceba17bb60b3e31950723d27e68c52f92118a2101a6223f59a55ff2fa84553975992015df722e3fc656b6f70da00cff0ffd04c60250fce2940f553ec30
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like