Sources of Error and Variability in Particulate Matter Sensor Network Measurements



Details

  • Personal Author:
  • Description:
    The quality of mass concentration estimates from increasingly popular networks of low-cost particulate matter sensors depends on accurate conversion of sensor output (e.g., voltage) into gravimetric-equivalent mass concentration, typically using a calibration procedure. This study evaluates two important sources of variability that lead to error in estimating gravimetric-equivalent mass concentration: the temporal changes in sensor calibration and the spatial and temporal variability in gravimetric correction factors. A 40-node sensor network was deployed in a heavy vehicle manufacturing facility for 8 months. At a central location in the facility, particulate matter was continuously measured with three sensors of the network and a traditional, higher-cost photometer, determining the calibration slope and intercept needed to translate sensor output to photometric-equivalent mass concentration. Throughout the facility, during three intensive sampling campaigns, respirable mass concentrations were measured with gravimetric samplers and photometers to determine correction factors needed to adjust photometric-equivalent to gravimetric-equivalent mass concentration. Both field-determined sensor calibration slopes and intercepts were statistically different than those estimated in the laboratory (a = 0.05), emphasizing the importance of aerosol properties when converting voltage to photometric-equivalent mass concentration and the need for field calibration to determine slope. Evidence suggested the sensors' weekly field calibration slope decreased and intercept increased, indicating the sensors were deteriorating over time. The mean correction factor in the cutting and shot blasting area (2.9) was substantially and statistically lower than that in the machining and welding area (4.6; p = 0.01). Therefore, different correction factors should be determined near different occupational processes to accurately estimate particle mass concentrations. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1545-9624
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    16
  • Issue:
    8
  • NIOSHTIC Number:
    nn:20058233
  • Citation:
    J Occup Environ Hyg 2019 Aug; 16(8):564-574
  • Contact Point Address:
    Thomas M. Peters, Department of Occupational and Environmental Health, 105 River St, S331 CPHB, University of Iowa, Iowa City, IA 52242-5000
  • Email:
    thomas-m-peters@uiowa.edu
  • Federal Fiscal Year:
    2019
  • Performing Organization:
    Johns Hopkins University, Baltimore, Maryland
  • Peer Reviewed:
    True
  • Start Date:
    20140901
  • Source Full Name:
    Journal of Occupational and Environmental Hygiene
  • End Date:
    20180831
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:b3f81d9cd64a017d725351002a4ca25513668aecee4f2f222e3db0e09581302b9721bc6e5c9173ef5276e716b1dd1b8d511c808fd9e5cb073b62e49ef08f0cf3
  • Download URL:
  • File Type:
    Filetype[PDF - 2.36 MB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.