Description:This article summarizes results of research conducted by the National Institute for Occupational Safety and Health (NIOSH) at its Pittsburgh Research Laboratory. The objective of this work was to determine the correlation between the mass (M) of respirable coal and limestone dusts collected on 25-mm-diameter glass fiber filters mounted in cassettes and the increase in differential pressure (deltaP) that develops across the filters when drawing at constant air flow. Test aerosols were generated inside a laboratory dust chamber using various coal dusts, limestone dust, and mixes of the two. Dusts with different particle size distributions were deposited on the filters by sampling from the chamber through cyclone preclassifiers at different flow rates. Results show that the relationship between differential pressure increase (cm water) and dust mass (mg) is linear and can be approximated by the equation deltaP = KM. The K values (slopes) range from 1.14 to 1.64, depending on the parent coal of the samples. The influence of particle size distribution was also found. The overall K value for all the data summarized in this article is 1.35, with R2 = 0.84 for the summary equation. When calibrated for individual work sites, or other circumstances where great variability in dust characteristics is avoided, the relationship between collected dust mass and increase in differential pressure may provide an exploitable principle for measurement of respirable dust concentrations. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Series:
-
ISSN:1047-322X
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:96-103
-
Volume:17
-
Issue:2
-
NIOSHTIC Number:nn:20022689
-
Citation:Appl Occup Environ Hyg 2002 Feb; 17(2):96-103
-
Federal Fiscal Year:2002
-
Peer Reviewed:True
-
Source Full Name:Applied Occupational and Environmental Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:1dcee035bf62f3d6dd66aec6d56063411e454d3b72494c58111d57d0084a938681a10305e20b4f8dd5cb26351360681f8bb8442be5bdc35e28a826fdaf64f53a
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like