Using Spectral Averaging and Signal Processing to Leverage Existing Short-Term Fence Line UV Spectroscopic Data to Retrieve Accurate, Long-Term Gas Concentrations to Meet New Monitoring Goals
-
2015/07/13
-
Details
-
Personal Author:
-
Description:In the near future, a rule proposed by the U.S EPA could require refining operations to conduct fence line monitoring for benzene. Some facilities have existing Ultra Violet Differential Optical Absorption Spectroscopes (UV DOAS) to perform fence line leak detection. The rule will require a lower limit of detection (LOD) of 1.0 parts-per-billion (ppb) benzene. The proposed timescale for one proposed method (passive samplers) is 14 days. Currently, the UV DOAS fence line systems are configured to sample every 5 minutes for leak detection. When utilizing the shorter timescale, low ppb LODs can be achieved, though not necessarily the proposed LOD of 1.0 ppb benzene. Theoretically, the LOD decreases as a function of the square root of the number of spectra averaged (sample time). This theory predicts that a 50 minute sample would have a LOD of less than 1/3 that of a 5 minute sample. Preliminary tests have shown a decrease of absorbance equivalent noise (AED) of 55% by increasing averaging time from 5 minutes to 40 minutes. With advanced signal processing to deal with changes in pressure (e.g., oxygen in the beam path) and signal strength changes over time, existing systems should be able to provide the existing leak detection capabilities while also providing chronic exposure information meeting or exceeding the requirements of the proposed rule. The 1.0 ppb benzene LOD should be achievable by averaging and processing only a few hours of data. This would allow for a much better temporal resolution than the proposed 14 day timescale making it possible to better use wind data to trace sources. In addition, the UV DOAS instruments are already configured to monitor for multiple compounds, so the same technique can be applied to get chronic exposures information for other gases such as toluene, p-xylene, sulfur dioxide, and carbon disulfide. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1
-
NIOSHTIC Number:nn:20053033
-
Citation:2015 National Environmental Monitoring Conference (NEMC), July 13-16, 2015, Chicago, Illinois. Weatherford, TX: The NELAC Institute, 2015 Jul; :1
-
Contact Point Address:R. Crampton, Argos Scientific, Inc., 3620 SE Sunrise Dr., Camas, WA , 98607, United States
-
Email:rcrampton@argos-sci.com
-
CAS Registry Number:
-
Federal Fiscal Year:2015
-
Performing Organization:University of North Alabama, Florence
-
Peer Reviewed:False
-
Start Date:20050701
-
Source Full Name:2015 National Environmental Monitoring Conference (NEMC), July 13-16, 2015, Chicago, Illinois
-
End Date:20270630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:e5ddba327ec4e2f138e5fd92ee4598562f041b7f888c824bd958ba4831e7c111f0a9a020a24e7f0bb8049fe06148579309150c8f5a080bc865b01fdf7cfcca7b
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like