Reductions in Exposures to Simulated Respiratory Aerosols by a Ceiling-Mounted HEPA Air Filtration Unit
Public Domain
-
2025/03/01
-
Details
-
Personal Author:
-
Description:Supplemental air filtration can reduce indoor exposure to hazardous aerosols without requiring modifications to building heating, ventilation, and air conditioning (HVAC) systems. Portable air cleaners were widely used during the COVID-19 pandemic, but they can have drawbacks including noise, space obstruction, and electrical cord safety considerations. Built-in air filtration units are an alternative to provide supplemental air filtration. We conducted a case study of a HEPA air filtration unit installed in the ceiling of a conference room using radial laminar flow or square cone ceiling air supply diffusers. A respiratory aerosol simulator exhaled aerosol particles (0.3 to 10 µm), and the particle concentrations were measured in the personal breathing zones of three breathing simulators representing a speaker and two meeting participants. For the speaker, using one square cone supply diffuser reduced inhalation exposure by 49 % to 81 % while using two square supply diffusers reduced exposure by 68 % to 93 %. For the participants, the exposures were reduced by 23 % to 64 % with one square supply diffuser and 58 % to 86 % with two square supply diffusers. Results when using the radial supply air diffusers were more variable and more dependent on the simulator layouts. Combining the use of cloth face masks on all simulators with the ceiling unit reduced the speaker's exposure by 87 % to 99 % and the participants' exposures by 84 % to 97 %. In most cases the ceiling air filtration unit provided protection against simulated respiratory aerosol particles comparable to that seen previously with portable air cleaners. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0360-1323
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:271
-
NIOSHTIC Number:nn:20070483
-
Citation:Build Environ 2025 Mar; 271:112611
-
Contact Point Address:William G. Lindsley, Health Effects Laboratory Division, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 1000 Frederick Lane, M/S 4020, Morgantown, WV 26508-5402, USA
-
Email:wlindsley@cdc.gov
-
Federal Fiscal Year:2025
-
Peer Reviewed:True
-
Source Full Name:Building and Environment
-
Collection(s):
-
Main Document Checksum:urn:sha-512:aa441cf64633d9ce5f6f557e89d8f0d03f59fe9e8ad49814ec6fc654a7d063b923fea4b0c40359662c48e29c89ed3db402c68725c6c17e7b947b97a8019b45b9
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like