Examining the Roles of Training, Fit Testing, and Safety Climate on User Confidence in Respiratory Protection: A Case Example with Reusable Respirators in Health Delivery Settings
Public Domain
Peer Reviewed
-
2023/09/01
Details
-
Personal Author:
-
Description:A lack of confidence in the efficacy of respiratory protection can contribute to uncertainty among workers and cast doubt on workplace safety. To date, no research has been conducted to study and understand the introduction of elastomeric half-mask respirators (EHMRs)-without exhalation valves (EVs) or with exhalation valve filters (EVFs), both representing new designs that address source control-in the workplace. To study this issue, researchers collaborated with partners at 32 health delivery settings that received EHMRs from the Strategic National Stockpile during the COVID-19 pandemic. EHMR users (n = 882) completed an online survey between October 2021 and September 2022. Analyses demonstrated that employees were statistically significantly more confident in the efficacy of EHMRs with no EV/with an EVF (including the efficacy in protecting the user from COVID-19) if they had been fit tested and received training. Respondents were also statistically significantly more confident in the efficacy of their EHMR if they had a more positive perception of their organization's safety climate. The results provide insights for tailored fit testing and training procedures as manufacturers continue to improve respirator models to enhance worker comfort and use. Results also show that, even during a public health emergency, the role of safety climate cannot be ignored as an organizational factor to support worker knowledge, attitudes, and participation in health and safety behaviors specific to respirator use. Description provided by NIOSH
-
Subjects:
-
Keywords:
- Training
- Fit testing
- Safety climate
- Respiratory protection
- Elastomeric half-mask respirators
- Respirator testing
- Health care facilities
- Emergency preparedness
- COVID-19
- Author Keywords: elastomeric half-mask respirator
- emergency preparedness
- fit testing
- healthcare
- program sustainability
- respiratory protection
- reusable respirator
- safety climate
-
ISSN:2071-1050
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:15
-
Issue:17
-
NIOSHTIC Number:nn:20068499
-
Citation:Sustainability 2023 Sep; 15(17):12822
-
Contact Point Address:Emily J. Haas, National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, PA 15236
-
Email:ejhaas@cdc.gov
-
Federal Fiscal Year:2023
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Sustainability
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:9fdac66966ddd543dc07a013ba961b1f542b050ac1bfc66e75873bc41e99a860a2278761d56ebd10dc8c726071dd454e4afff8be9103ed6bda49ff7b00f2a78d
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like