U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

The performance evaluation of aerosol samplers tested with monodisperse aerosols

Public Domain Peer Reviewed


Details

  • Personal Author:
  • Description:
    Two methods for estimating the performance characteristics of aerosol samplers were discussed. The methods were the polygonal approximation (PA) method and the curve fitting (CF) method. The PA method estimated the mean concentration of a sampled aerosol by approximating the integral of the sampling efficiency curve and the normalized distribution of the aerosol particles by a series of polygons. The variance of the estimated mean concentrations was expressed in terms of intersample and residual variations of the measured efficiency values. The CF method estimated a mean concentration for each sampled aerosol by fitting a curve to the efficiency values for that specimen using linear or nonlinear least square regression techniques. The methods were evaluated by applying them to published data on fluorescent tagged monodisperse aerosols obtained using MRE 113A static samplers and PM-10 ambient aerosol samplers. Estimates of sampler efficiency, sampler bias, and imprecision were obtained using each method and compared. The two methods generally produced comparable results when applied to the data obtained with the PM-10 sampler. The PA method gave poorer results for aerosol size distributions than the CF method when assessed by the magnitude of the geometric standard deviation of the mean. The data obtained with the MRE 113A sampler were generally not amenable to analysis by the CF method due to a small number of data points, which led to large uncertainties in the estimates of sampler efficiency, sampler bias, and precision. The authors conclude that when the PA and CF methods are applied to aerosol sampling data, they generally produce similar results when analyzing monodisperse aerosols. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0021-8502
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    109-126
  • Volume:
    26
  • Issue:
    1
  • NIOSHTIC Number:
    nn:00227085
  • Citation:
    J Aerosol Sci 1995 Jan; 26(1):109-126
  • Federal Fiscal Year:
    1995
  • Peer Reviewed:
    True
  • Source Full Name:
    Journal of Aerosol Science
  • Download URL:
  • File Type:
    Filetype[PDF - 1.49 MB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:df3d6a59624b5532383804881d2d140b7a1a34c17f17c2e6dbe31014210ae073e8d84eee6001b1b24178ece3f9bfaf68f92d7d0d38a7650823d09234ac7778b9
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.