The effect of respirator dead space and lung retention on exposure estimates
-
1993/12/01
Details
-
Personal Author:
-
Description:The effects of respirator dead space and lung retention on inhalation exposure estimates were examined. Equations expressing the effects of respirator dead space and lung retention on inhalation, exhalation, and full cycle equilibrium average contaminant concentrations inside a respirator were derived for filter penetration and face seal leakage or no filter penetration and face seal leakage. The equations were based on mass transfer relations and assumed that air entering the filters was mixed with exhaled air or not mixed (plug flow condition). For a dead space volume of zero, no mixing was predicted to occur and the difference between the inhaled and exhaled contaminant concentrations was maximal. For nonzero dead space volumes, the difference between the inhaled and exhaled concentrations decreased with increasing volume. The presence of a face seal leak resulted in a higher average in/respirator contaminant concentration than the no leakage condition. During the plug flow condition, a greater proportion of the contaminant could enter the mask, but was not inhaled, and consequently would not be retained in the respiratory tract. The validity of the equations was evaluated by comparing their predicted average concentrations with concentrations measured during a laboratory simulation. A mannequin fitted with a quarter, half, or full face respirator was connected to a breathing machine. Dead space volumes of 0.14 to 1.73 times the respirator volume were used. Polydisperse and monodisperse aerosols of oleic-acid tagged with uranine dye were used as the test aerosol. Concentrations predicted for good mixing of inhaled and exhaled air showed the best agreement with the experimental values. Concentrations predicted for the plug flow condition showed the worst agreement. The dead spaces reduced the average in/respirator aerosol concentrations by up to 50%. The authors conclude that respirator dead space and lung retention can reduce average inhaled contaminant concentrations in a respirator by as much as 50%. The effect increases with increasing head space volume. Areas in which the equations can be applied are discussed, including fit factor evaluations, respirator performance modeling, and workplace protection factor studies. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:54
-
Issue:12
-
NIOSHTIC Number:nn:00218597
-
Citation:Am Ind Hyg Assoc J 1993 Dec; 54(12):711-722
-
Contact Point Address:Inst of Safety & Systems Mgmt University of California University Park Los Angeles, Calif 90089-0021
-
Federal Fiscal Year:1994
-
Performing Organization:University of Southern California, Los Angeles, California
-
Peer Reviewed:True
-
Start Date:19840701
-
Source Full Name:American Industrial Hygiene Association Journal
-
End Date:19940630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:bf1a1e10e44a9eacb1ba766ec5daf2cd4911b5c8bf235bbef8377dc2cf43163b42c11d74156942bd0c442e29c1a121299c4c8b7e2a10f03aa1d782dc542a5605
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like