Evaluation of new in-facepiece sampling procedures for full and half facepieces
Public Domain
-
1993/04/01
Details
-
Personal Author:
-
Description:The bias and precision associated with five new in/face respirator sampling procedures was evaluated. The procedures evaluated consisted of a continuous, low sampling rate flush on the respirator midnose and mouth probing (CLF) procedure; a continuous, high sampling rate deep front of mouth probing (CHD) procedure; a pushed exhalation, deep front of mouth probing (PED) procedure; an exhalation valve discharge (EVD) procedure; and a pulsed inhalation, deep front of mouth pushing (PID) procedure. The CLF procedure was the recommended methodology for sampling respirator facepieces in the United States. The procedures were evaluated using nine full facepieces and five half facepieces. All facepieces were normally equipped with organic vapor cartridges and were NIOSH certified. The full facepieces did not have nose cups. The facepieces were punctured at three sites to generate leaks corresponding to penetrations of 1 or 0.1% and mounted on a specially designed respirator/simulated breathing test system. Acetone vapor was used as the test agent. The amounts of acetone vapor passing through the leaks were measured using the CLF, CHD, PED, EVD, and PID. The bias for each procedure was determined as the difference between the true acetone concentration and the concentrations measured inside the facepieces. Precision was estimated using a modified analysis of variance technique. The average sampling biases on the full facepieces obtained with the CLF, CHD, PED, EVD, and PID procedures were -21, -3, 0.7, -14, and -12.3%, respectively. The corresponding biases on the half facepieces were -26, -13, -4, -2, and -24%. The precision of the measurements obtained on the full facepieces by the CLF, CHD, PED, EVD, and PID procedures were 14.0, 11.8, 5.0, 11.9, and 21.0%, respectively. The values obtained on the half facepieces were 14.0, 11.7, 5.8, 3.0, and 29.2%, respectively. The authors conclude that based on the results obtained with the full facepieces the PED is the best procedure and the CLF procedure the worst. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Genre:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:151-166
-
Volume:37
-
Issue:2
-
NIOSHTIC Number:nn:00216104
-
Citation:Ann Occup Hyg 1993 Apr; 37(2):151-166
-
Federal Fiscal Year:1993
-
Peer Reviewed:True
-
Source Full Name:Annals of Occupational Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:b66f8de5340852660ee6df8ee88b2765f8091965308c9c699711946a784b7c42c196ee56249d660ecf4f3a16bc481797a2d82f40814bb81b08405695158c0e4e
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like