Cost-effective radiator repair ventilation control

Public Domain


Details

  • Personal Author:
  • Description:
    A cost effective ventilated enclosure for controlling lead (7439921) exposures during radiator repair work was described. The enclosure was designed in response to a health hazard evaluation at three radiator repair shops in the Denver, Colorado area that found breathing zone lead concentrations as high as 290 micrograms/cubic meter (microg/m3) and blood lead concentrations above 40 microgram/deciliter in three of ten mechanics. The OSHA standard for lead is 50microg/m3. The ventilated enclosure consisted of a 1.5 millimeter thick curtain of silicone coated fiber glass cloth that was suspended from the ceiling to form a tent like structure over the water bath that was used to test radiators for leaks. A 100 centimeter (cm) wide by 90cm high opening in the front of the enclosure permitted the mechanic to repair the radiator inside the enclosure. A propeller fan having an exhaust rate of 3400 cubic meters/hour was mounted in the rear (outside) wall of the enclosure. This produced an air flow of 1 meter/second through the enclosure that was directed to the shop exhaust. The cost of the enclosure excluding the fan was 600 dollars. The ability of the enclosure to control lead exposures was evaluated by collecting breathing zone samples during radiator repair operations in one of the shops. Breathing zone samples were also analyzed at a workstation in the same shop that did not have the enclosure. Time weighted average lead exposures were reduced from 453 to 9.9microg/m3 by the enclosure. The authors conclude that the ventilated enclosure provides very good control of lead exposures generated during radiator repairs. Because it is not expensive it can be used by most small and medium size shops. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1047-322X
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    6
  • Issue:
    11
  • NIOSHTIC Number:
    nn:00203322
  • Citation:
    Appl Occup Environ Hyg 1991 Nov; 6(11):959-965
  • CAS Registry Number:
  • Federal Fiscal Year:
    1992
  • Peer Reviewed:
    True
  • Source Full Name:
    Applied Occupational and Environmental Hygiene
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:48be0a401fe7275d690590ce333056b3c5df2cf3d29d7c7bce10dca8a29522d336bce278f71d84c49e8cc4d89d0a8501043c48baef238acf44ffffd017720600
  • Download URL:
  • File Type:
    Filetype[PDF - 893.43 KB ]
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.