Review and evaluation of hand-arm coordinate systems for measuring vibration exposure, biodynamic responses, and hand forces
Public Domain
-
2015/09/01
-
Details
-
Personal Author:
-
Description:The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:2093-7911
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:159-173
-
Volume:6
-
Issue:3
-
NIOSHTIC Number:nn:20046698
-
Citation:Saf Health Work 2015 Sep; 6(3):159-173
-
Contact Point Address:Ren G. Dong, Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, 1095 Willowdale Road, MS L-2027, Morgantown, WV 26505
-
Email:rkd6@cdc.gov
-
Federal Fiscal Year:2015
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Safety and Health at Work
-
Collection(s):
-
Main Document Checksum:urn:sha-512:2ba0b2d52970151ed55c6e182c712a625f02d4b73d83c5532607f089c4f0fa7e1f904e9bda9a8fb2fc7343ca2b4f4163b5eb03d9957d391290356d5572b82ed9
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like