Eggcrate UV: a whole ceiling upper-room ultraviolet germicidal irradiation system for air disinfection in occupied rooms
Peer Reviewed
-
2014/04/01
Details
-
Personal Author:
-
Description:A novel whole ceiling upper-room ultraviolet germicidal irradiation (UVGI) system eggcrate ultraviolet (UV) has been developed that incorporates open-cell 'eggcrate'-suspended ceiling panels and bare UV lamps with a ceiling fan. Upper-room UVGI is more effective for air disinfection than mechanical ventilation at much lower installation and operating costs. Conventional upperroom UVGI fixtures employ multiple tightly spaced horizontal louvers to confine UV to the upper-room. These louvered fixtures protect occupants in the lower-room from UV-induced eye and skin irritation, but at a major cost to fixture efficiency. Using a lamp and ballast from a conventional upper-room UVGI fixture in the eggcrate UV system, the germicidal efficacy was markedly improved even though the UV radiation emitted by the lamp was unchanged. This fundamental change in the application of upper-room UVGI air disinfection should permit wider, more effective application of UVGI globally to reduce the spread of airborne infection. Description provided by NIOSH
-
Subjects:
-
Keywords:
- Airborne-particles
- Air-contamination
- Germ-cells
- Ultraviolet-light
- Germicides
- Disinfectants
- Ventilation
- Author Keywords: Airborne disease transmission
- Upper-room ultraviolet germicidal irradiation
- Infection
- Bioaerosol
- Air disinfection
- Whole ceiling ultraviolet germicidal irradiation system
- Eggcrate ultraviolet
-
ISSN:0905-6947
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:116-124
-
Volume:24
-
Issue:2
-
NIOSHTIC Number:nn:20046085
-
Citation:Indoor Air 2014 Apr; 24(2):116-124
-
Contact Point Address:E. Nardell, Department of Environmental Health, Harvard School of Public Health, Boston, MA 02115
-
Email:enardell@gmail.com
-
Federal Fiscal Year:2014
-
NORA Priority Area:
-
Performing Organization:Brigham and Women's Hospital, Boston, Massachusetts
-
Peer Reviewed:True
-
Start Date:20060801
-
Source Full Name:Indoor Air
-
End Date:20170731
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:47f8fcb0eb957510889f6cc6a1d6173e5eb505e0bcf2f88b0d0cd7598778b7bca5376d2d25ca8015b34db690a8823302650069204ab4765f4cac9a5b9de65001
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like