U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Factors influencing the airborne capture of respirable charged particles by surfactants in water sprays



Details

  • Personal Author:
  • Description:
    This research measured the effects of particle diameter, surfactant-containing spray solution, and particle charge on the capture of respirable particles by surfactant-containing water spray droplets. Polystyrene latex particles with diameters of 0.6, 1.0, or 2.1 um were generated in a wind tunnel. Particles were given either a neutralized, unneutralized, net positive, or net negative charge, and then were captured as they passed through sprays containing anionic, cationic, or nonionic surfactant. The remaining particles were sampled, charge-separated, and counted with the sprays on and off at varying voltage levels to assess collection efficiency. Overall efficiencies were measured for particles with all charge levels, as well as efficiencies for particles with specific charge levels. The overall collection efficiency significantly increased with increasing particle diameter. Collection efficiencies of 21.5% +/- 9.0%, 58.8% +/- 12.5%, and 86.6% +/- 43.5% (Mean +/- SD) were observed for particles 0.6, 1.0, and 2.1 um in diameter, respectively. The combination of surfactant classification and concentration also significantly affected both overall spray collection efficiency and collection efficiency for particles with specific charge levels. Ionic surfactant-containing sprays had the best performance for charged particles with the opposite sign of charge but the worst performance for charged particles with the same sign of charge, while nonionic surfactant-containing spray efficiently removed particles carrying relatively few charges. Particle charge level impacted the spray collection efficiency. Highly charged particles were removed more efficiently than weakly charged particles. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1545-9624
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    11
  • Issue:
    9
  • NIOSHTIC Number:
    nn:20044741
  • Citation:
    J Occup Environ Hyg 2014 Sep; 11(9):571-582
  • Contact Point Address:
    Mei Tessum, University of Minnesota, Division of Environmental Health Sciences,MayoMail Code 807, 420 Delaware Street S.E., Minneapolis, MN 55455
  • Email:
    wang1443@umn.edu
  • Federal Fiscal Year:
    2014
  • Performing Organization:
    University of Minnesota
  • Peer Reviewed:
    True
  • Start Date:
    20090915
  • Source Full Name:
    Journal of Occupational and Environmental Hygiene
  • End Date:
    20130914
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:47380ad46a2cbfcebfb6d1cab2b9a88aeff3ea876c02a1b6b4ec3049a3f42ddf9f7f3ebf7cc2dc6d479cd6c1bbb8513213c611f7460277f42573b7e2ebf62f93
  • Download URL:
  • File Type:
    Filetype[PDF - 963.77 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.