Total evaporative resistance for five different clothing ensembles at different humidity levels and work demand
-
2004/05/01
-
Details
-
Personal Author:
-
Description:With regard to heat stress, the limiting factor inherent in clothing ensembles is the total evaporative resistance. For the same work demands, the greater the evaporative resistance of the clothing, the lesser the ability to cool by sweat evaporation and hence the lower the environmental contributors to heat stress, especially water vapor pressure, must be. Knowing the evaporative resistance provides a means to compare candidate ensembles. Further, a value for evaporative resistance means that a rational method, such as the ISO Required Sweat Rate, can be used to assess the heat stress exposure. PURPOSE: Evaporative resistance of five clothing ensembles (cotton work clothes, cotton coveralls, and three coveralls of particle barrier (PB), micro-porous (MP) and vapor barrier (VB) properties) was determined empirically from wear tests. METHODS: For Yr1, the metabolic rate was held constant at 160 W/m2, and three levels of humidity (20, 50, 70% rh) were explored. Fourteen heatacclimated participants (9 men and 5 women) completed trials for all combinations of clothing ensemble and environment. In the Yr2 study, the humidity was held constant at 50% rh, and three levels of metabolic rate (114, 176, 250 W/m2) were explored. Fifteen heat-acclimated participants (11 men and 4 women) completed trials for all combinations of clothing ensemble and environment. The data from both years was combined and analyzed using ANOVA. RESULTS: Significant differences were found among ensembles (p<0.0001). As expected, VB coveralls had the highest resistance at 0.035 kPa m2/W. Micro-porous was next at 0.029; followed by PB and coveralls at 0.027. Work clothes was 0.026 kPa m2/W. Pair-wise comparisons adjusted for multiple comparisons were used to locate the differences among ensembles. VB was different from all others and MP was different from work clothes. From the year two study, we found that evaporative resistance decreased with increased metabolic rate. CONCLUSIONS: Data from both studies support that there are differences in evaporative resistances among different clothing ensembles. The decreased evaporative resistances in year 2 can be explained by the pumping action associated with increased work. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0195-9131
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:36
-
Issue:5
-
NIOSHTIC Number:nn:20044045
-
Citation:Med Sci Sports Exerc 2004 May; 36(5)(Suppl 1):S313-314
-
Email:vcaravel@hsc.usf.edu
-
Federal Fiscal Year:2004
-
Performing Organization:University of South Florida, Tampa, Florida
-
Peer Reviewed:False
-
Start Date:20000930
-
Source Full Name:Medicine and Science in Sports and Exercise
-
Supplement:1
-
End Date:20040929
-
Collection(s):
-
Main Document Checksum:urn:sha-512:652661df560b1d0f67dd398376e8da94e6463b6d91dd2075e8de19c8ea97284aac936ca49d094371ebec2b8597f6a520023c892e3c403c8964f9e07d052a256e
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like