Photoacoustic FTIR spectroscopy for crystalline silica analysis
Public Domain
-
1998/05/09
-
Details
-
Personal Author:
-
Description:The National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods includes three laboratory methods for measuring crystalline silica: X-ray diffraction (XRD), infrared spectroscopy (IR), and colorimetry (VIS). The purpose of this study was to determine if photoacoustic Fourier transform infrared (PA-FTIR) spectroscopy could be a viable alternative for laboratory analysis of crystalline silica samples. One benefit of PA-FTIR spectroscopy is that it is a nondestructive direct-on-filter method. In a preliminary study, crystalline silica dusts were generated using a fluidized-bed aerosol generator with a quartz stock standard (Min-U-Sil 5). The size distributions of the generated aerosols were determined using a mico-oriface uniform deposit impactor. The samples used in the PA-FTIR analysis were collected using 9-mm portions of 2S-mm vinyl metricel (VM-l) filters loaded into 25-mm cassettes, which were attached to nylon cyclones, at a flow rate of 1.7 L/min. The respirable crystalline silica dust samples were weighed and then analyzed by PA-FTIR spectroscopy. Samples with different masses were collected. Multiple measurements of the samples were conducted to determine reproducibility of the analysis technique. The mass medium aerodynamic diameter of the samples on the filters was estimated to be 1.0 mm with a geometric standard deviation of 1.8 by correcting the size distribution from the impactor samples using the ACGIH definition of respirable particulate mass. A calibration curve was constructed. The limit of detection was determined to be less than 10 mg of quartz. Using 32 FTIR scans for each measurement, the relative standard deviation of replicate measurements of one filter was below 10%. These preliminary data indicate that PA-FTIR is worth additional study to determine whether it may be valid laboratory method for direct-on-filter measurement of crystalline silica. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:75
-
NIOSHTIC Number:nn:20044037
-
Citation:American Industrial Hygiene Conference and Exposition, May 9-15, 1998, Atlanta, Georgia. Fairfax, VA: American Industrial Hygiene Association, 1998 May; :75
-
CAS Registry Number:
-
Federal Fiscal Year:1998
-
Peer Reviewed:False
-
Source Full Name:American Industrial Hygiene Conference and Exposition, May 9-15, 1998, Atlanta, Georgia
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d814337a60ab70a7ece2d3150167b2338332316f4903e351e4aade545bac1f0d68b034878c1bd19b05658090955196993bae933a54d3041fcce2c49e515ede77
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like