Simulated workplace performance of N95 respirators
Public Domain
-
1998/05/09
-
Details
-
Personal Author:
-
Description:The National Institute for Occupational Safety and Health (NIOSH) has received many inquiries about the face-fitting characteristics of the new N95 respirators. These inquiries raised the issues of how well do these respirators fit, whether N95 respirators have to be fit-tested, and whether they can be quantitatively fit-tested. In response, researchers of the NIOSH Certification and Quality Assurance Branch evaluated the performance of 12 N95 respirator models on a panel of 25 subjects with varying face sizes. The performance of each respirator model was assessed in two ways: first, on the panel of 25 subjects not fit-tested and, second, after removing from the panel those subjects failing a fit test. Total penetration, the combination of filter penetration and face seal leakage, was measured for each panel member. The 95th-percentile of the total penetration values was then computed for each model. The 95th-percentile of the total penetration that is typically used to indicate overall respirator performance indicates that 95% of the wearers can expect to have a total respirator penetration less than this value. The 95th-percentile total penetration without fit-testing for the 12 respirators ranged from 5 to 77%. A properly fitted half-mask respirator is expected to have a total penetration less than 10%. When the first donning was used as a surrogate fit-test to screen out poor fits, the 95th-percentile of the total penetration decreased to 2 to 4%, a significant increase in protection. Therefore, this study suggests that this level of protection is achieved only when fit-testing is performed to screen out poor face fits. The results also indicate that fit-testing is an essential element of a respirator program. Without fit-testing, the protection provided by this class of respirator is unreliable. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:61
-
NIOSHTIC Number:nn:20043990
-
Citation:American Industrial Hygiene Conference and Exposition, May 9-15, 1998, Atlanta, Georgia. Fairfax, VA: American Industrial Hygiene Association, 1998 May; :61
-
Federal Fiscal Year:1998
-
Peer Reviewed:False
-
Source Full Name:American Industrial Hygiene Conference and Exposition, May 9-15, 1998, Atlanta, Georgia
-
Collection(s):
-
Main Document Checksum:urn:sha-512:036dad483e6acfdd94e6035ed20cba561627d89fb2d25677aaebb90f320f94efc055d02c7ec631731a24cd3206e3677dcb2694fee1d4de09d9cb93fbdcd9f531
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like