Getting optimal performance from a powered air-purifying respirator (PAPR) depends on the condition of its battery!
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Getting optimal performance from a powered air-purifying respirator (PAPR) depends on the condition of its battery!

Filetype[PDF-247.96 KB]


  • English

  • Details:

    • Description:
      "The guidance in this fact sheet will help respiratory protection program administrators, managers, and powered air-purifying respirator (PAPR) wearers understand the importance of a PAPR's battery in assuring effective respiratory protection. The respiratory protection program administrator should assure that PAPR manufacturer recommendations for battery storage, care, usage, and disposal are addressed. However, an understanding of these requirements by managers and PAPR wearers is also beneficial to ensure personal protection. The National Institute for Occupational Safety and Health (NIOSH) approves a PAPR as an assembly of components, which are listed on the full NIOSH approval label packaged with the unit. The battery is a crucial component of an approved PAPR assembly and must operate the assembly for a minimum period of four hours. The PAPR must be used with its manufacture-specified battery and provide the NIOSH-required air flow rates. A NIOSH-approved PAPR may include more than one battery type. However, for each alternate battery there is a specific assembly of components required to assure the PAPR performs to NIOSH standards. Use of components not listed on the NIOSH full approval label for the PAPR and air-purifying component constitutes an assembly not evaluated by NIOSH and may result in serious injury and/or death to the wearer. If the battery is not in proper operating condition, it may not supply the PAPR with a sufficient charge to perform properly, which could place the PAPR wearer at risk of personal injury or death. Therefore, it is important to know the battery's storage, use, care, and disposal requirements to assure effective personal protection. The instructions supplied with a PAPR might not include all of this information, so it is also essential to reference the instructions provided with the battery and battery charger." - NIOSHTIC-2

      NIOSHTIC no. 20043125

      2013-146.pdf?id=10.26616/NIOSHPUB2013146

    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov