Evaluation of protective ensemble thermal characteristics through sweating hot plate, sweating thermal manikin, and human tests
Public Domain
-
2014/04/01
-
Details
-
Personal Author:
-
Description:The purpose of this study was to evaluate the predictive capability of fabric Total Heat Loss (THL) values on thermal stress that Personal Protective Equipment (PPE) ensemble wearers may encounter while performing work. A series of three tests, consisting of the Sweating Hot Plate (SHP) test on two sample fabrics and the Sweating Thermal Manikin (STM) and human performance tests on two single-layer encapsulating ensembles (fabric/ensemble A = low THL and B = high THL), was conducted to compare THL values between SHP and STM methods along with human thermophysiological responses to wearing the ensembles. In human testing, ten male subjects performed a treadmill exercise at 4.8 km and 3% incline for 60 min in two environmental conditions (mild=22.C, 50% relative humidity (RH) and hot/humid = 35.C, 65% RH). The thermal and evaporative resistances were significantly higher on a fabric level as measured in the SHP test than on the ensemble level as measured in the STM test. Consequently the THL values were also significantly different for both fabric types (SHP vs. STM:191.3 vs. 81.5 W/m2 in fabric/ensemble A, and 909.3 vs.149.9 W/m2 in fabric/ensemble B (p < 0.001). Body temperature and heart rate response between ensembles A and B were consistently different in both environmental conditions (p < 0.001), which is attributed to significantly higher sweat evaporation in ensemble B than in A (p < 0.05), despite a greater sweat production in ensemble A (p < 0.001) in both environmental conditions. Further, elevation of microclimate temperature (p < 0.001) and humidity (p < 0.01) was significantly greater in ensemble A than in B. It was concluded that: (1) SHP test determined THL values are significantly different from the actual THL potential of the PPE ensemble tested on STM, (2) physiological benefits from wearing a more breathable PPE ensemble may not be feasible with incremental THL values (SHP test) less than approximately 150-200 W·m2, and (3) the effects of thermal environments on a level of heat stress in PPE ensemble wearers are greater than ensemble thermal characteristics. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1545-9624
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:259-267
-
Volume:11
-
Issue:4
-
NIOSHTIC Number:nn:20043832
-
Citation:J Occup Environ Hyg 2014 Apr; 11(4):259-267
-
Contact Point Address:Dr. Aitor Coca, National Personal Protective Technology Laboratory (NPPTL/NIOSH/CDC), 626 Cochrans Mill Road, B29-107, Pittsburgh, PA 15236
-
Email:esq6@cdc.gov
-
Federal Fiscal Year:2014
-
Peer Reviewed:True
-
Source Full Name:Journal of Occupational and Environmental Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:c8095d400fc3119d2483866ac0525235c47de7ff88eb8b86cc5266e9811a6094f588609c9729eb4ea46bf03f40aedc369d2d872760b6967f41616f4fbd3a737c
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like