Performance Characteristics of the Button Personal Inhalable Aerosol Sampler
-
2000/05/01
-
Details
-
Personal Author:
-
Description:The button inhalable aerosol sampler with a curved porous inlet recently was developed and evaluated as a stationary sampler in the laboratory and in the field. The present study focused on investigating its suitability for personal inhalable aerosol sampling. The button sampler was tested at two wind velocities (0.5 and 2.0 m/sec), three particle sizes (7, 29, and 70 microm) and three orientations to the wind (0, 90, and 180 degrees). The performance characteristics of the button sampler were compared with those of three other personal samplers--the IOM (Institute of Occupational Medicine), GSP, and 37-mm closed-face filter cassette. The experiments were conducted in a wind tunnel with the samplers mounted on a full-size manikin. The direction-specific sampling efficiency of the button sampler was found to be essentially independent of the wind direction and dependent on the wind velocity to a much smaller degree than that of the three other samplers. When direction-averaged, the fit of its sampling efficiency curve to the inhalability curve was found to be better than that of the 37-mm closed-face cassette, comparable with that of the GSP sampler, and less than that of the IOM sampler. The precision of the button sampler was found to be generally equal to or better than the precision of the comparison samplers. It was concluded that the button sampler can be successfully used as a personal inhalable aerosol sampler. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:398-404
-
Volume:61
-
Issue:3
-
NIOSHTIC Number:nn:20020602
-
Citation:Am Ind Hyg Assoc J 2000 May/Jun; 61(3):398-404
-
Contact Point Address:S.A. Grinshpun, Aerosol Research and Exposure Assessment Laboratory, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267-0056
-
Federal Fiscal Year:2000
-
NORA Priority Area:
-
Performing Organization:University of Cincinnati, Cincinnati, Ohio
-
Peer Reviewed:True
-
Start Date:19980201
-
Source Full Name:American Industrial Hygiene Association Journal
-
End Date:20020131
-
Collection(s):
-
Main Document Checksum:urn:sha-512:ff711b0177b24f83f4b19e3c132f19bbe42703352c776d313544127628a359adf95f9618f2c990e3550ff8d2c2505685b7ec46c96620d9e3b906475d02c0a288
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like