U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Evaluation of Virtual Source Beam Configurations for Rapid Tomographic Reconstruction of Gas and Vapor Concentrations in Workplaces



Details

  • Personal Author:
  • Description:
    An evaluation of virtual source beam configurations for rapid tomographic reconstruction of gas and vapor concentrations in workplaces by open path/Fourier Transform infrared (OP/FTIR) spectroscopy was performed. Three virtual source beam configurations generated for a single beam steerable OP/FTIR system were tested in a 24 by 21 feet (ft) chamber. The first had the spectrometer placed at the center of the chamber with 52 flat mirrors placed along the perimeter of the chamber and a retroreflector placed at each of the four corners. The second had the spectrometer placed at the center of the chamber, 52 flat mirrors placed along the perimeter of the chamber, two retroreflectors at each of the four corners, and 44 small retroreflectors placed between the flat mirrors. The third configuration had the spectrometer placed at the center of the chamber, 56 flat mirrors placed along the perimeter of the chamber, and 56 small retroreflectors placed between the mirrors. The three configurations were evaluated numerically by calculating Gaussian peak concentration profiles for an air contaminant released in the chamber which were then used to reconstruct a map of the contaminant concentrations in the chamber by computed tomography (CT). The pixel size for the calculations was set at 1.6 by 1.6ft which resulted in a 13 by 15 CT reconstruction grid. The calculated CT maps for each configuration were then compared to experimental CT maps reconstructed from data obtained when sulfur-hexafluoride was released into the chamber. Calculated CT maps generated with the third configuration, with 56 flat mirrors and 56 small retroreflectors arrayed along the perimeter of the chamber, showed the best agreement with the experimental data. Reconstructed maps for all configurations, however, showed some unrealistic artifacts such as very steep and high concentration gradients at some pixels. The authors conclude that despite the minor artifacts, the third beam configuration could be applied in many industrial situations with reasonable cost and resources. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1096-2247
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    47
  • Issue:
    5
  • NIOSHTIC Number:
    nn:00241849
  • Citation:
    J Air Waste Manage Assoc 1997 May; 47(5):582-591
  • Contact Point Address:
    Environmental & Indust Health University of Michigan 1420 Washington Heights Ann Arbor, MI 48109-2029
  • Federal Fiscal Year:
    1997
  • NORA Priority Area:
  • Performing Organization:
    University of Michigan at Ann Arbor, Ann Arbor, Michigan
  • Peer Reviewed:
    True
  • Start Date:
    19890901
  • Source Full Name:
    Journal of the Air and Waste Management Association
  • End Date:
    19990929
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:f289140c306feb8147e7fa539f8bc03af831ff46544ba4584a937749893c9e06230f290957daaa964e6fcdb5c785c58aafa8768526b2394bd3e06e7bdb511411
  • Download URL:
  • File Type:
    Filetype[PDF - 569.77 KB ]