Comparison of the Companion and Modified PortaCount Methods for Fit Testing N95 Respirators
Public Domain
-
1999/10/10
-
Details
-
Personal Author:
-
Description:In 1995, the National Institute for Occupational Safety and Health (NIOSH) revised the particulate respirator performance regulations contained in Title 42 Code of Federal Regulations, Part 84. Soon after questions arose regarding whether N95 respirators (one of the new classes of particulate respirators) could be quantitatively fit tested. In response, NIOSH and TSI Incorporated researchers developed a method for fit testing N95 filtering-facepiece respirators using the PortaCount Plus. The PortaCount Plus fit test was designed to measure fit factors (i.e., face seal leakage only). Due to some N95 filter media having significant penetration of ambient particles, the PortaCount Plus when used with a N95 respirator may not measure just face seal leakage but total penetration (i.e., filter penetration and face seal leakage). Total penetration was converted to face seal leakage by subtracting out filter penetration. A filter ratio test clamp was developed to measure filter penetration with the PortaCount Plus. TSI also developed a new accessory (the N95-COMPANION for the PortaCount Plus) to fit test N95 respirators. The purpose of this study was to determine how well the fit factors from these two methods correlate. The facepiece fit of each respirator model was measured on a panel of subjects with varying face sizes. A "standard" PortaCount Plus test was conducted for each subject/respirator combination. Immediately after the "standard" PortaCount Plus test, a fit test for each subject/respirator combination was conducted using the N95-COMPANION in conjunction with the PortaCount Plus without the respirator being redone. After the N95-COMPANION test, filter penetration was measured on each respirator using the PortaCount Plus with the clamp, and an adjusted fit factor computed. The results of analysis of variance indicated that the geometric mean of the N95-Companion fit factor (49) was not significantly different from the geometric mean of the adjusted fit factor (35). [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1
-
NIOSHTIC Number:nn:20023191
-
Citation:ISRP International Conference 1999 Oct; :1
-
Contact Point Address:National Institute for Occupational Safety and Health, MS H-117, 1095 Willowdale Road, Morgantown, WV 26505-2888, USA
-
Federal Fiscal Year:2000
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:International Society for Respiratory Protection International Conference, Pittsburgh, PA, October 10-14, 1999
-
Collection(s):
-
Main Document Checksum:urn:sha-512:3e2abd0583447e8d786a3d9e0c25564dd28882dc9aaccb20a074359d17023a047debd7a76e20e8cada5a1fc46b34e61687d6bedcb69d9bd3b157034146ea3e59
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like